Product Manual
Table Of Contents
- Section 1: Safety Rules & General Information
- Section 2: General Information
- Section 3: Activation and Startup
- Section 4: Operation
- Section 5: Maintenance
- Component Locations
- Access Panels
- Maintenance
- Remove From Service
- 25 Hour Break-In
- Daily Maintenance
- Schedule A Maintenance
- Schedule A Maintenance Item Locations
- Preliminary Instructions
- Inspecting the Enclosure Louvers
- Inspecting the Fuel Lines
- Inspecting Coolant Level and Hoses
- Inspecting Radiator for Clogging
- Checking Lubricating Oil Level and Drain Hose
- Replacing Lubricating Oil and Oil Filter
- Checking Battery Condition/Fluid Level
- Inspecting Accessory/Drive Belt
- Replacing Air Filter Element
- Final Instructions
- Schedule B Maintenance
- Schedule C Maintenance
- Return To Service
- Section 6: Troubleshooting
Maintenance
Owner’s Manual for Spark-Ignited Stationary Generators 25
Service Maintenance Schedule
Observe the maintenance tasks and intervals shown in the table below.
NOTE: If the unit reaches a Schedule A or Schedule B maintenance interval with 900 to 999 total hours, have an IASD
perform the Schedule C maintenance tasks as well (and reset the A-B-C/Year maintenance schedule counter).
Service
25 Hours
Engine Break-In
Daily If Running
Continuously
Schedule A
Every Year
or 125 Hours
Schedule B
Every 2 Years
or 250 Hours
Schedule C
Every
1000 Hours
Inspect enclosure louvers
• • • •
Inspect fuel hoses
• • • •
Inspect coolant level and hoses
• • • •
Inspect radiator for clogging
• • • •
Inspect lubricating oil level and drain hose
• • • •
Replace lubricating oil and oil filter*
• • • •
Inspect battery condition/fluid level
• • •
Inspect/adjust accessory/drive belt tension
• • •
Replace air filter element
• • •
Drain/flush coolant system
• •
Clean/gap/replace spark plugs
• •
Tighten critical fasteners
•
* 1 year or 200 hours per oil change, whichever comes first.