Product Manual
A Spark Plugs
B Battery
C Oil Drain Hose
D Coolant Drain
E Coolant Overflow Reservoir
A
B
C
D
E
Maintenance
30 Owner’s Manual for Stationary Generators
Figure 5-3. Left Side View
NOTE: All
normal maintenance and service items are
easily accessible for consumer convenience. Wherever
possible, touch points are colored orange to provide for
quick and easy recognition.
Access Panels
Access panels are located at both the left and right sides
of the enclosure.
Removal
1. Insert key (B) into latch and rotate counterclock-
wise 1/2 turn. See Figure 5-4.
2. Raise pa
nel using thumb latch (A).
A
B
006370
Figure 5-4. Access Panel Key and Latch (Typical)
Installation
1. Lower panel into position using thumb latch.
2. Inser
t key into latch and rotate clockwise 1/2 turn.
Maintenance
Regular maintenance will improve performance and
extend engine/equipment life. Generac Power Systems,
Inc. recommends that all maintenance work be per-
formed by an Independent Authorized Service Dealer
(
IASD). Regular maintenance, replacement, or repair of
the emissions control devices and systems may be per-
formed by any repair shop or person of the owner’s
cho
osing. To obtain emissions control warranty service
free of charge, the work must be performed by an IASD.
See the emissions warranty.
(000182a)
WARNING
Equipment damage. Only qualified service personnel may
install, operate, and maintain this equipment. Failure to
follow proper installation requirements could result in death,
serious injury, and equipment or property damage.
It is important to perform all maintenance at the interval
specified in the Service Maintenance Schedule. This
en
sures safe and proper operation, as well as
compliance with applicable emissions standards