Spec Sheet
16 of 18
®
D3.3L G16 132 Gal Tank (1 of 2)
Installation Drawings15 • 20 • 30 • 48 • 50 kW
Protector™
1625 [64.0]
TYP
173 [6.8]
888 [35.0]
OVERALL WIDTH
2424 [95.4]
OVERALL LENGTH
182 [7.2]
TYP
1691 [66.6]
OVERALL
HEIGHT
897 [35.3]
DOOR WIDTH
TYP
608 [23.9]
EXHAUST OUTLET
581
[22.9]
998
[39.3]
CENTER OF GRAVITY
SEE NOTE 5
SERVICE ITEM D3.3L
OIL FILL CAP LEFT
OIL DIP STICK LEFT
OIL FILTER LEFT
OIL DRAIN HOSE RIGHT
RADIATOR DRAIN HOSE RIGHT
COOLANT RECOVERY BOTTLE RIGHT
RADIATOR FILL CAP ACCESS ROOF
AIR CLEANER ELEMENT RIGHT
MUFFLER FRONT
FAN BELT EITHER
BATTERY RIGHT
WEIGHT DATA WITH EMPTY BASETANK
(SEE NOTE 5)
GENERATOR AS SHOWN 1102 [2429]
WITH WOODEN SHIPPING SKID 1147 [2529]
RADIATOR/EXHAUST 
DISCHARGE AIR
AIR INTAKE
(BOTH SIDES)
RADIATOR/EXHAUST 
DISCHARGE AIR
(BOTH SIDES)
REFERENCE OWNERS MANUAL FOR 
PERIODIC REPLACEMENT PART LISTINGS
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2718 (107") LONG.
 REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT
 FOR CONCRETE PAD GUIDELINES
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
 AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
 APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
 STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
 - SEE SPECIFICATION SHEET OR OWNERS MANUAL
 - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF
 GENERATOR
4. REMOVE THE REAR TANK AND REAR ENCLOSURE COVER PANEL TO ACCESS
 THE STUB-UP AREAS AS FOLLOWS:
 - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
 NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
 - LOW VOLTAGE CONNECTIONS INCLUDING TRANSFER SWITCH CONTROL WIRES
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. ENGINE SERVICE CONNECTIONS
 OIL DRAIN: 3/8" NPT
 EXHAUST OUTLET: 2" O.D.
7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
 AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
9. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5 
 (USE STANDARD SAE TORQUE SPECS)
WEIGHT: KG [LBS]
DIMENSIONS: MM [INCH]
REAR VIEW
REAR ENCLOSURE 
COVER PANEL
SEE NOTE 4
CIRCUIT BREAKER
SEE NOTE 3
CUSTOMER ACCESS 
ASSEMBLY, CONTROL 
PANEL ACCESS, 
BATTERY CHARGER 
LOCATED WITHIN
SEE NOTE 4
REMOVABLE 
STUB-UP 
COVER
SEE NOTE 4
RIGHT SIDE VIEW
LIFTING PROVISION (4 PLACES) 
SEE NOTES 5, 8 AND CENTER 
OF GRAVITY DIMENSIONS
VISE ACTION LATCH, ONE 
PER DOOR, ONE LIFT-OFF 
DOOR ON FRONT, RIGHT 
AND LEFT SIDES
LIFT-OFF DOOR PROVIDES ACCESS TO: FUEL 
FILL, FUEL LEVEL GAUGE, NORMAL VENT, 
INNER TANK EMERGENCY VENT, OUTER TANK 
EMERGENCY VENT, OPTIONAL 90% ALARM 
ASSEMBLY, OPTIONAL 5 GALLON SPILL BOX
LEFT SIDE VIEW
EXHAUST MUFFLER 
ENCLOSED WITHIN 
GENERATOR ENCLOSURE
OPEN PUNCHED 
LOUVERS TYPICAL ON 
BOTH SIDES OF FUEL 
TANK VENTILATION 
DUCT TO PROVIDE 
ADEQUATE CROSS-FLOW 
OF AIR VENTILATION
FUEL TANK 
VENTILATION 
DUCT
TOP VIEW
BATTERY 12 VOLT 
NEGATIVE GROUND
REMOVE PANEL TO 
ALLOW TANK VENTS 
TO TERMINATE OUTSIDE 
OF THE GENERATOR 
ENCLOSURE (CHECK 
LOCAL AND STATE 
CODE FOR 
APPLICABILITY)
INTERNAL DIVIDER PANEL SEPARATES 
FUEL TANK VENTILATION DUCT FROM 
THE ENGINE, ALTERNATOR AND 
EXHAUST SYSTEM
REMOVE COVER FOR 
ACCESS TO RADIATOR 
FILL CAP