Portable Generator User Manual
  STANDBY  PRIME
  SG010  SG015  SG010  SG015 
GENERATOR OUTPUT VOLTAGE/KW-60Hz    NG/LP   Rated AMP  NG/LP   Rated AMP  NG/LP   Rated AMP  NG/LP    Rated AMP
  120/240V, 1-phase, 1.0 pf    10    41.7  15    62.5  7.2    30.0  11    45.8
  120/208V, 3-phase, 0.8 pf    10    34.7  15    52.1  7.2    25.0  11    38.2
  120/240V, 3-phase, 0.8 pf    10    30.1  15    45.2  7.2    21.7  11    33.1
  277/480V, 3-phase, 0.8 pf    10    15.1  15    22.6  7.2    10.8  11    16.6
MOTOR STARTING KVA
  Maximum at 35% instantaneous voltage dip 
    with standard alternator; 60 Hz    20      29      20      29
FUEL   
  Fuel consumption—60 Hz—100% Load    N.G.    L.P.  N.G.    L.P.  N.G.    L.P.  N.G.    L.P.
    ft.
3
/hr.  185    77  265    110  145    60  204    85
    m
3
/hr.  5.2    2.2  7.5    3.1  4.1    1.7  5.8    2.4
COOLING
  Coolant capacity  System lit.(US gal.)   6.6 (1.75)   6.6 (1.75)    6.6 (1.75)   6.6 (1.75)
    Engine lit.(US gal.)   0.9 (0.25)   0.9 (0.25)    0.9 (0.25)   0.9 (0.25)
    Radiator lit.(US gal.)   6.6 (1.75)   6.6 (1.75)    6.6 (1.75)   6.6 (1.75)
  Coolant flow/min.  60 Hz lit.(US gal.)    25 (6.6)     25 (6.6)     25 (6.6)    25 (6.6)
  Heat rejection to coolant  60 Hz BTU/hr.    48,000     72,000      35,000    53,000
  Cooling air flow  60 Hz m
3
/min. (cfm)   40 (883)    40 (883)    40 (883)    40 (883)
COMBUSTION AIR REQUIREMENTS
  Flow at rated power  60 Hz m
3
/min. (cfm)    0.8 (29)     1.2 (41)     0.6 (22)    0.9 (32)
EXHAUST
  Exhaust flow at rated output  60 Hz m
3
/min. (cfm)   2.7 (96)    3.9 (137)     2.1 (75)    3.0 (32)
  Max. recommended back pressure  Kpa (Hg)   5.0 (1.5")   5.0 (1.5")    5.0 (1.5")   5.0 (1.5") 
  Exhaust temp. at rated output   
o
C (
o
F)   593 (1100)   621 (1150)   566 (1050)   593 (1100)
  Exhaust outlet size   N.P.T. (female)    1.5"      1.5"      1.5"      1.5"
ENGINE
  Rated RPM  60 Hz    1800      1800      1800      1800
  HP at rated KW  60 Hz    15      23      11      17
  Piston speed  60 Hz m/min. (ft./min.)    295 (969)   295 (969)    295 (969)   295 (969) 
  BMEP (psi)  60 Hz - psi    77      116      55      85
POWER ADJUSTMENT FOR AMBIENT CONDITIONS
  Temperature 
    -3% for every 10
o
C above - °C    40      25      40      25
    -1.5% for every 10
o
F above - °F    104      77      104      77
  Altitude
    -3% for every 300 m above - m    913      150      913      150
    -3% for every 1000 ft. above - ft.    3000      500      3000      500
OPERATING DATA
SG010 / SG015