User's Manual

3
The setup is fast and consists of the following steps:
1. Connect a CAT5 (RJ45) or higher category cable between
each monitor (and subwoofer) and finally to the control
network input of the GLM Adapter device (see Figure 1).
2. Connect the GLM Adapter device to computer USB
connector.
3. Using a microphone stand, place the Genelec measurement
microphone at the listening location with the microphone
pointing upwards and the microphone top at the height of
the engineer’s ear. The microphone is a part of the GLM
User Kit.
4. Connect the microphone cable to the microphone input in
the GLM Adapter device.
5. Download the GLM software at the Genelec web site (www.
genelec.com).
6. Install the GLM software and follow the instructions in the
software to measure and set up your monitors.
7. If you plan to not use a computer for controlling the
monitors, use the GLM software to write the setting into the
monitors (use menu item “Group | Store Group Settings”).
GLM calculates the acoustic compensation for the room in a
cloud computer. This enables always up-to-date methods and
efficient calculation process. The Stored Settings function using
the Genelec Loudspeaker Manager software can be used to
store calibration settings into the monitors.
Once the GLM network is disconnected, the calibrated stored
settings using the Genelec Loudspeaker Manager software can
be selected in use by setting the STORED switch to the ON
position found on the rear of the monitor.
Figure 2. Connectors and local controls on the back panel
of a S360A.
Figure 1. GLM control network cabling
Figure 3. Connector panel detail.
MICROPHONE
PLACED IN
THE LISTENING
POSITION
292-0063
GLM
TERMINATOR
COMPUTER
RUNNING
GLMSOFTWARE
USB CABLE
GLM ADAPTER
GLM NETWORK
CABLE
MONITORS
ANALOG
IN
DIGITALTHRU
AES/EBU
DIGITALIN
AES/EBU
GLM
NETWORK
MAINSINPUT
50 /60Hz 200 W
100 - 240 V~
WARNING: ELECTRIC SHOCK HAZARD.DONOT OPEN.DO NOT SUBJECTTO
WATER OR MOISTURE. NO USERSERVICEABLE PA RTSINSIDE. REFER
SERVICING TO QUALIFIED PERSONNEL. USEEARTHED MAINS CONNECTION
ONLY.
AVERTISSEMENTRISQUE DE CHOC ÉLECTRIQUE. NE PASOUVRIR.NEPAS
EXPOSERÀL'EAU OU L'HUMIDITÉ. AUCUNCOMPOSANT ÀL'INTÉRIEUR
REMPLAÇABLEPAR L'UTILISATEUR. ADRESSERTOUTERÉPARATIONÀUN
PERSONNELQUALIFIÉ. CETAPPAREILDOIT ÊTRERACCORDÉÀLA TERRE.
LAITEONLIITETTÄVÄSUOJAKOSKETTIMILLA VARUSTETTUUN PISTORASIAAN.
APPARATET TILKOPLESJORDET STIKKONTAKT.
APPARATENSKALLANSLUTASTILLJORDATUTTAG.
This devicecomplieswithFCCPart15 and CanadianICES-003 radio frequency
Class Bemission requirements. Referto operating manualfor fullinformation.
292-S360AT-6
MADE IN FINLAND
S360A
SERIAL NUMBER
www.genelec.com
RESET TO FACTORY
SETTINGS: PUSH
BUTTON FOR10 SEC
SENSITIVITY
IN dBu FOR
100 dB SPL (1m)
-2
+4
+2
-4
-6
+6
dBu
0
20 160
+2
-2
-4
dB
-6
0
4k 20k
BASS
TILT
800
BASS
ROLL-OFF
DESKTOP
ALLOFF
TREBLE
TILT
Frequency (Hz)
(dB)dB)
ON
OFF
BASS ROLL-OFF
BASS TILT
-2
-2
TREBLE TILT
+2
DESKTOP160 Hz -4
LEDDIS ABLE
A
-20dB
B
STORED
-10dB
LEVEL
DIGITAL
ISS
-4
-4
-4
TONE CONTROLS
FUNCTION SWITCHES:
- LED DISABLE
- ISS
- DIGITAL A/B
- LEVEL
-STORED
SENSITIVITY
CONTROL
POWER/RESET
SWITCH
MAINS
CONNECTOR
GLM NETWORK
CONNECTORS
DIGITAL IN,
DIGITAL THRU AND
ANALOG IN