User Manual
>110 cm (43 in)
Main
monitor
<60cm (24 in)
Figure 3. Recommended distances to
the front wall
Figure 1. 7040A's amplifier panel, connectors and controls.
Figure 2. XLR to RCA connector for  
connecting to an unbalanced signal source.
panel. The default position from the factory 
is with "ISS DISABLE" in the OFF position. 
Installation
The subwoofer is supplied with a mains 
cable and this operating manual. After 
unpacking inspect the subwoofer for pos-
sible damage in transport. Ensure that the 
subwoofer and the monitors are powered 
o before connecting cables. 
Audio connections to the subwoofer 
and monitors use balanced XLR cables 
(not included in the subwoofer delivery 
content). As the 7040A has an integrated 
amplier,  it  may  only  be  connected  to  a 
line level signal source, such as a mixing 
console or preamplier, never to the loud-
speaker outputs of a power amplier or an 
integrated amplier.
The source is connected to the "LEFT 
IN" and "RIGHT IN" connectors of the 
subwoofer. The subwoofer’s output con-
nectors "LEFT OUT" and "RIGHT OUT" are 
connected to the monitors. 
If the signal source has unbalanced 
RCA outputs, you can use signal cables as 
shown in Figure 2.
Once all connections have been made, 
the subwoofer and monitors can be pow-
ered up.
Positioning In The Room
Placement of the subwoofer in the room 
aects the subwoofer frequency response 
and sound level dramatically, as the room 
influences the low frequencies strongly. 
Even a slight change in the subwoofer's 
location can make a marked  dierence in 
the frequency balance. Often patient and 
methodical experimentation is needed to 
nd the optimum placement. The placement 
will also aect the phase alignment between 
the monitors and the subwoofer, as well as 
the need for bass roll-o adjustment. 
First, place the subwoofer slightly oset 
from the center of the front wall. The dis-
tance to the nearest wall should be less 
than 0.6 m (24 in) measured from the sub-
woofer's driver. This position increases 
acoustic loading and sound output due to 
the proximity of the wall and oor. Too large 
a distance from the wall can cause cancel-
lations and reduce subwoofer output. The 
monitor should be placed at least 1.1 m (43 
in) away from walls to avoid reduction of 
low frequency output (see Figure 3).
If the subwoofer frequency response does 
not seem balanced, move the subwoofer 
slightly to the left or right. This changes 
how the room modes are excited and can 
MADE IN FINLAND
www.genelec.com
7040A ACTIVE SUBWOOFER
MAGNETICALLY SHIELDED
SERIAL
NUMBER
LEFT OUT
LEFT IN
RIGHT OUT
RIGHT IN
POWER
ON
ROLL-OFF
-180°
-90°
-4 dB
-2 dB
-270°
ISS-DISABLE
MAINSINPUT
50 /60Hz70W
100 - 240 V~
-6
0
+6
+3
+12
-3
-4
dBu
SENSITIVITY
FOR 100 dB
SPL @1m
SIGNAL INPUT
CONNECTORS
SIGNAL OUTPUT
CONNECTORS
BASS ROLL-OFF
PHASE AND
ISS DISABLE
SWITCHES
MAINS INPUT
POWER SWITCH