User's Manual
LTE Outdoor Gateway Quick Installation Guide
Installing the IDU
The IDU can only be mounted indoors. It should be mounted on any horizontal surface, such as a desktop or shelf. Be
sure to select a suitable location for the device within 100 m (328 ft.) of the ODU. Consider these guidelines:
• Select a cool, dry place, which is out of direct sunlight.
• The device must be near an AC power outlet that provides 100 to 240 V, 50 to 60 Hz with proper grounding.
• The device should be accessible for network cabling.
• The overall length of the Ethernet cables from the ODU to the IDU and from the IDU to the PC must not exceed 100m.
You must plan a cable route from the ODU to the IDU indoors. Consider these guidelines:
• Determine a building entry point for the cable.
• Determine if conduits, bracing, or other structures are required for safety or protection of the cable.
• For additional lightning protection, it is recommended to use a lightning arrestor immediately before the Ethernet cable
enters the building.
Connecting the Cables
Figures 2 demonstrates ODU CPE connected to an IDU (supply unit –PoE)
RJ-45 and telephone line have to be connected to LTE outdoor CPE.
• Follow the instruction on PoE adapter: RJ-45 port (“TO/FROM OSU POE RJ45) connects to ODU through RJ-45 cable,
meanwhile, RJ-14 port (“TO/FROM OSU VOIP) and outdoor CPE can be connected by telephone line.
• Using a phone line connected the telephone with RJ-11 port on POE adapter.
• Available for other device such as PC/Hub/Switch connected to PoE through RJ-45 cable on PoE.
Figure 2:CPE Connections
Connect the indoor unit to the AC mains using the power adapter supplied with the unit.
Do not connect the data equipment to the PoE port on the IDU, as it supplies DC power to the ODU, and this
may harm other equipment connected to it.
CAUTION
!
3