User's Manual
ODU Installation
Mounting the ODU
Mount the ODU unit using the supplied kit:
Preparing the PoE-ODU Cable
Use a crimp tool for RJ-45 connectors to prepare the wires. Insert them into the appropriate pins and use the tool
to crimp the connector. Make sure to do the following:
Remove as small a length as possible of the external jacket. Verify that the external jacket is well inside the
sealing cover when connected to the unit, to ensure good sealing.
Pull back the shield drain wire before inserting the cable into the RJ-45 connector, to ensure a good
connection with the connector's shield after crimping.
Connecting the PoE-ODU Cable
1. Follow the detailed instructions supplied with the sealing cap to assemble the sealing cap onto the cable: Strip
the cable sheath. Insert the screw nut into the housing. Insert the seal at the back end of the housing. Insert
the cable all the way through. Crimp the RJ-45 plug. Insert the plug into the housing. Then secure the sealing
nut in place. Stricken the gasket on the front end of the housing.
2. Connect the Ethernet cable to the RJ-45 connector of the ODU.
3. Use appropriate sealing material to protect the connection against moisture and humidity. Use high quality
sealing material such as Scotch® 130C Linerless Rubber Splicing Tape from 3M to ensure IP-67 compliant
protection against dust and water.
4. Route the cable to the location selected for the PoE.
5. Assemble an RJ-45 connector with a protective cover on the PoE end of the POE-ODU cable. Refer to the pin
assignment and color codes in standard cables described below.