Quick Installation Guide

PRO 6000 CPE Quick Installation Guide
P/N 216000 -6- May 2012
3 Seal the connector:
a Attach the mastic tape (Scotchfil™ Electrical Insulation Putty) and wrap it around the connector butting up against the
connector. Do not over stretch.
b Squeeze to tighten the mastic sealer. Make sure there are no air bubbles.
c Slide the cold shrink sleeve on top of the connector. Make sure that the sleeve covers both cable connector and unit
connector.
d Pull the cord slowly to shrink the sleeve.
Indoor Connections
1 Assemble an RJ-45 connector with a protective cover on the other end of the IDU-ODU cable. Refer to the pin assignment
and color codes in standard cables described above.
2 Connect the other end of the IDU-ODU cable to the single connector on the IDU, labeled “TO/FROM ODU PoE (RJ45)” (see
Figure 4).
3 Connect one end of the supplied Ethernet cable to a PC/Hub/Switch.
4 Connect the other end of the Ethernet cable to the IDU port, labeled with a computer illustration (see Figure 4).
5 Use a telephone cable to connect a phone to the connector labeled with a telephone illustration (see Figure 4)
6 Connect the indoor unit to the AC mains using the power adapter supplied with the unit.
Checking for Proper Operation
1 Verify data connectivity by sending a ping command to the BTS or by connecting to the Internet.
2 Check the LED functionality according to the following table:
Figure 8: Cold Shrink Tubing
CAUTION
Do not connect the data equipment to the PoE port on the IDU, as it supplies DC power to the ODU, and this
may harm other equipment connected to it.
Description Color Functionality
Fault + Ethernet indication LED Red
Lights at start up
During the built-in test (BIT) blinks (300ms on, 300ms off)
Off/On - If BIT completed successfully. If BIT failed, it continues
lightning
On - If fatal error/critical alarm appears during run time
Blinking - If PoE Ethernet is connected and no errors found (1sec
on, 3sec off).
WiMAX W/L link availability LED Green
Lights at start up
Off - upon BIT completion
Blinking - the CPE is synchronized with the BS and 5> SNR 3dB.
On - when the CPE is synchronized with the BS and the SNR 5dB
Cold Shrink Seal
Cold Shrink Sleeve
Cord