Quick Installation Guide

PRO 6000 CPE Quick Installation Guide
P/N 216000 -5- May 2012
1 Prepare the cable: Use a crimp tool for RJ-45 connectors to prepare the wires. Insert them into the appropriate pins and use
the tool to crimp the connector. Make sure to do the following:
» Remove as small a length as possible of the external jacket. Verify that the external jacket is well inside the sealing cover
when connected to the unit, to ensure good sealing.
» Pull back the shield drain wire before inserting the cable into the RJ-45 connector, to ensure a good connection with the
connector's shield after crimping.
The following figure shows the required wire pair connections. The color codes used in standard cables supplied by the
manufacturer are as listed in the table:
2 Connect the cable (see Figure 6):
a Remove the sealing gland plug from the gland nut.
b Open the sealing gland nut and remove it. Do not disassemble the gland base from the bracket.
c Insert the cable into the sealing gland base and connect it to the RJ-45 connector at the bottom of the CPE, labeled
.
Make sure that the connector is completely inserted and tightened.
d Insert the rubber bushing on the cable into the gland base.
e Tighten the gland nut. Use the dedicated tool for fastening the sealing glands.
Wire color
Pin
Blue 1
Blue/white 2
Orange 3
Orange/white 6
Brown 4
Brown/white 5
Green 7
Green/white 8
Figure 5: Ethernet Connector Pin Assignments
Figure 6: Inserting the Cable into the Sealing Cap
Figure 7: Sealing Gland Fastening Tool