Quick Installation Guide

PRO 6000 CPE Quick Installation Guide
P/N 216000 -4- May 2012
Installing The IDU
The IDU can only be mounted indoors. It should be mounted on any horizontal surface, such as a desktop or shelf. Be sure to
select a suitable location for the device within 100 m (328 ft.) of the ODU. Consider these guidelines:
Select a cool, dry place, which is out of direct sunlight.
The device must be near an AC power outlet that provides 100 to 240 V, 50 to 60 Hz with proper grounding.
The device should be accessible for network cabling.
The overall length of the Ethernet cables from the ODU to the IDU and from the IDU to the PC must not exceed 100m.
You must plan a cable route from the ODU to the IDU indoors. Consider these guidelines:
Determine a building entry point for the cable.
Determine if conduits, bracing, or other structures are required for safety or protection of the cable.
For additional lightning protection, it is recommended to use a lightning arrestor immediately before the Ethernet cable enters
the building.
Connecting the Cables
Outdoor Connections
Connecting the Grounding Cable
Connect a grounding cable between the Ground terminal of the ODU (marked ) and a good ground connection.
Preparing and Connecting the IDU-ODU Cable
Use only Category 5E 4x2x24# FTP outdoor cables from an approved manufacturer. The cable provides pin-to-pin connection on
both ends.
CAUTION
Use ONLY the power adapter supplied with the IDU. Otherwise, the product may be damaged.
Figure 4: CPE Connections
LEDs
PoE
Input/Output serial
console (debug or
distribution automation
ODU
IDU
CAT 5 Ethernet cable
Grounding