User Manual Part 3
User’s Guide Version 1.0
Firmware auto-update:
Auto-update function allows update device firmware automatically. This function will help for large
enterprises, having hundreds of AC's, to keep them up to date.
Figure 207 – Firmware Auto-update Configuration
Status - defines if auto-update is enabled or disabled. Default value disabled.
Update URL - defines where firmware should be downloaded from. It points directly to firmware
update file. URL should be accessible without any user authentication. URL can use HTTP, HTTPS
and FTP protocols. Default value - empty string.
Update interval – define the time interval between each update in hours [1-9999]. Time is counted
from last device boot-on. Default value is 48 hours.
Delay – delays update process by given amount of hours. This should prevent from getting hundreds
requests for firmware download at the same time [0-24]. Default value is 0.
Save - save new firmware auto-update settings.
On boot auto-update feature checks for available updates on specified server at
given URL. If there is different version - device downloads, installs firmware update
and reboots. If firmware version matches current version on device - no update
takes place.
BROWAN Page