Datasheet
G-8
FLOW SWITCHES
Visit www.GemsSensors.com for most current information.
Flow
Settings
GPM
1
Brass Stainless Steel
1/2˝ NPT Male 3/8˝ NPT Male 3/8˝ NPT Male 3/8˝ Compression 1/2˝ Barb
0.15 — 181130 193482 212136 239693
0.25 192562 168432 179992 177592 239692
0.50 192563 168433 179993 177593 239691
1.00 192564 168434 179994 177594 239690
1.50 192566 168435 179995 177595 239689
2.00 192567 178353 179996 225525 239688
FS-380 Series / p1of1 / 30-JUL-14
Gems FS-380
4.0
(102)
1.25
(32)
FLOW
7/8˝ HEX
24˝-26˝
LEAD WIRES
Gems FS-380
3.45
(88)
0.85
(22)
1.00
(25)
3/4˝ HEX
FLOW
24˝-26˝
LEAD WIRES
11/16˝ HEX
4.02
(102)
0.86
(22)
1.13
(29)
FLOW
24˝-26˝
LEAD WIRES
1.16
(29.5)
2 PLCS
24˝-26˝
LEAD WIRES
4.63
(117.6)
0.518
(13.1)
0.605
(15.4)
Gems FS-380
FLOW
0.836
(21.2)
1.13
(29)
3/4˝ A/F HEX
14
12
10
8
6
4
2
0
0 1 2 3 4 5 6 7
FLOW RATE - GPM
PSI DROP
SPRING 170342
1.5 + 2.0 GPM
SETTINGS
SPRING 10397
0.15 - 1.00 GPM
SETTINGS
inch
(mm)
G
E
M
S
C
O
M
P
L
I
A
N
T
®
R
o H S
G
E
M
S
C
O
M
P
L
I
A
N
T
®
R
oHS
FS-380 Series – Compact Flow Switch
for High Inline Pressures
Flow Rate Settings: 0.15 GPM to 2.00 GPM
Port Size: Multiple
Primary Construction Material: Brass or Stainless Steel
Setting Type: Fixed
These rugged inline flow switches require 100 micron filtration and are less
susceptible to clogging than other high-pressure inline flow switches. The one-
piece magnetic PPS composite piston makes the FS-380 ideal for high-pressure
applications such as industrial cleaning equipment. The FS-380 is also an excellent
choice for semicon cooling applications where simple design and reliable operation
are required.
Specifications
Wetted Materials
Housing Brass or 316 Stainless Steel
Piston PPS Composite, Epoxy
Spring 316 Stainless Steel
O-Ring Fluorocarbon
Operating Pressure, Maximum 1500 PSI (107 bar); 500 PSI (34 bar) for 1/2˝ Barb Models
Operating Temperature -20°F to +275°F (-28.8°C to +135°C)
Set Point Accuracy ±20% Maximum
Set Point Differential 20% Maximum
Switch* SPST, 20VA, N.O. at no Flow
Electrical Termination No. 22 AWG, 24˝ to 26˝ Polymeric leads
*See “Electrical Data” on Page X-5 for more information.
How To Order – Standard Models
Specify Part Number based on flow settings.
Spacing
To prevent sensor to sensor magnetic field interference, follow the spacing
guidelines below.
U.L. Recognized
File No. E31926
Dimensions
1/2˝ NPT Ports
3/8˝ NPT Ports
3/8˝ Tube End Compression Fitting
1/2˝ Hose Barb Fitting
Pressure Drop – Typical
– Stock Items.
Note:
1. Flow settings are calibrated using water @ 70°F on increasing flow with units in horizontal position.
Consult factory for other fluid compatibility.
2 13/64˝
1 1/4˝
2 3/8˝
1 1/2˝
FLOW
Gems FS-380
FLOW
Gems FS-380
FLOW
Gems FS-380
FLOW
Gems FS-380
NOTE SWITCH