USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ КЕРІВНИЦТВО КОРИСТУВАЧА
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Silver Shield programmable surge protector with LAN interface Silver Shield programmierbare und fernbedienbare Steckdosenleiste mit LANAnschluss Silver Shield programmeerbare stekkerdoos met LAN interface Silver Shield Boîtier commandé à distance et programmable avec prise LAN Программируемый сетевой фильтр с LANинтерфейсом Програмований мережевий фільтр з LANінтерфейсом 2 All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 1. Introduction Congratulations with your purchase of this Silver shield Power Manager. Your SIS-PMS-LAN is an advanced surge protector with power management features. Four sockets are individually manageable via the LAN interface. The sockets can be switched on/off by a timer schedule, by user or different events.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE • • • • • • The manageable sockets can then be switched on and off by the schedule, simple typical applications could be: “switch my peripherals on every working day at 8:50 AM” etc The manageable sockets can also be programmed with Power Manager software to react whenever a certain event occurs (Windows or other programs start-up/shutdown), simple typical applications could be: “switch my scanner on when I want to scan” or “switch my printer o
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 1.2. Specifications • • • • • • • • Input voltage: 220 – 230 VAC, 50 – 60 Hz Maximum load: 10 A Maximum power consumed by SIS-PMS-LAN: 2.5 W Built in power supply and battery Hardware schedule features: • Maximum number of independent hardware schedule events – 16 per socket • Time interval between the events – from 1 minute to 180 days • Timer accuracy: no more than 2 seconds error per day providing power is always present.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 1.3. Hardware requirements • • • Local area network with RJ45 sockets Any Internet-enabled computer connected to the local area network Computer running Windows® 2000/XP/Vista or Windows 7 is required for using the Power Manager software (use of this software is not compulsory) 1.4.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 2.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 2.1.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 2.2.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 2.3.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 3. Installation • • It is strongly recommended to avoid damp or wet places for installation. SIS-PMS-LAN should be connected to the European AC wall socket of the standard DIN 49 440. 3.1. Getting started • • • • Connect SIS-PMS-LAN to the wall socket first and then to the LAN socket (or your computer LAN card) with the provided patch cord or vice-versa. SIS-PMS-LAN can now be switched on and off by means of the Main rocker switch (Z).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE • • • • • • • The sockets: Socket 1, Socket 2, Socket 3 and Socket 4 can be managed or pre-programmed by computer via LAN. They are called manageable sockets in this manual. The manageable sockets of SIS-PMS-LAN can be programmed to be on or off. The current status of each manageable socket is represented by the corresponding indicator which will be lit if socket has power to it.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE remove the excessive load first and then press the Circuit breaker button to restore the power supply (see figure #3 above). To be able to use SIS-PMS-LAN you will now have to complete its LAN configuration. 3.2. Preparing LAN configuration of SIS-PMS-LAN Before configuring SIS-PMS-LAN hardware settings, please, let it obtain its IP address.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE • • • • • • • IP: 192.168.0.254 Subnet mask: 255.255.255.0 Gateway: 192.168.0.1 DNS:0.0.0.0 DHCP: enabled IP filtering: disabled Power Manager client port: 5000 .. and then search for an IP address from your eventual DHCP server If no DHCP server is found within 30 seconds, SIS-PMS-LAN will then automatically revert to the default settings (see above, with IP: 192.168.0.254) and additionally disable DHCP option. 3.3.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE NOTE: Antivirus or firewall software may block connection to SISPMS-LAN. Please, configure antivirus/firewall to permit connection to the IP address and port of your SIS-PMS-LAN 3.4. IP configuration The utility Find SIS-PMS-LAN (see Figure #4 below) will run automatically during the software installation but it can also be started from Start/All Programs/Gembird/Power Manager.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #4 The window of your default internet browser will be then opened to give you access to the built-in web-server. See section 4 below for the further details.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 4. The web server Your SIS-PMS-LAN is equipped with a web-server which allows managing the device using any web browser such as Internet Explorer etc. 4.1. Web-server login page To access the web server of SIS-PMS-LAN, just open Internet Explorer (or other browser) and input the IP address of SIS-PMS-LAN (for example http://192.168.1.241).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE After a successful login you will face the Socket 1 Status page (see section 4.2 below). NOTE: There is a possibility that you might then need to open the LAN settings page (see section 4.3 below) to complete the IP configuration. 4.2. Socket page There are 4 manageable sockets on SIS-PMS-LAN and so there are 4 pages corresponding to them.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #6 19 All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Below the page you can see the current time of the web-server and eventual information about the last successful timer synchronization. Automatic timer synchronization is used if Use NTP for timer correction option is enabled (see section 4.4 below). NOTE: If a certain socket has a switching fault, e.g.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #7 21 All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Choose the date and time of the scheduled event. If you wish the events to be executed periodically then check the Loop option and set the loop period. To commit to your changes press the Apply button. To delete the entered schedule press the Clear schedule button. NOTE: The hardware schedule keeps running even when the device is powered off.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 4.3.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE On the LAN settings page (see Figure #8 above) you can set up DHCP, IP address, Subnet mask, Gateway, DNS server and IP filter (up to 3 IP addresses can then be enabled for remote access). The new settings will be applied immediately after you press the Apply button. IP address, Subnet mask, Gateway, DNS server will be used only if the DHCP option is disabled.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 4.4. Device settings page On the device settings page you can setup name, password and internal time of SIS-PMS-LAN (see Figure #9 below).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE To be able to setup the schedule of SIS-PMS-LAN you have to first setup its internal clock correctly. Enter the current local time and date. Alternatively if the option Use NTP for timer correction is enabled (by default) then the time will be taken from NTP server. The device will try to connect with the server every 18 hours. The first synchronization would take place in 15 seconds after you press the Apply button.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Don’t forget to push the Apply button to save your settings. 4.5. Web-server logout Having finished working with SIS-PMS-LAN, choose Log Out in the main menu. If you don’t do this, you will be logged automatically after 10 minutes of inactivity. While you are logged to the web server, it can’t be accessed from any other computer.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 5. Power Manager software The Power Manager software is designed to support not only SISPMS-LAN but also other products of SIS family (SIS-BT, SIS-PM, SISPMS, MSIS-PM etc). 5.1. Finding SIS-PMS-LAN To be able to manage preconfigured SIS-PMS-LANs, please, do the following: • Install Power Manager software v.4.0.0.0 (or higher) on a PC connected to your local network.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #10 The LAN devices window (see Figure #11 below) will appear, click Add button there to add a new SIS-PMS-LAN device.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #11 In the Add LAN device window (see figure #12 below) please, enter correct IP address, port number (5000 by default) and password (1 by default) as configured on the Device settings page (see section 4.4 above) of the web server. To disconnect from the device uncheck the option Enable, set this option again to regain the access. Click OK button to return to the LAN devices window.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #12 Specified device should then appear with a green square next to it and Connected status in the LAN devices window (see Figure #13 below).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #13 • To edit the LAN device, select it and click the Edit button, or just double click on the LAN device • To remove the LAN device, select it and click the Remove button. You can select multiple LAN devices using Ctrl and Shift keys. You can also remove all LAN devices by clicking the Clear button HINT: Use the popup menu which can be activated by the right mouse button click over the table.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE If the status of SIS-PMS-LAN shows the device not to be Connected - it could be due to the following reasons: • Incorrect IP/Port/Password specified in the Add LAN device window • PC is not connected to the local network • You are trying to access SIS-PMS-LAN from the PC which is not allowed to do so. Change PC IP address or change IP filter list in SIS-PMS-LAN hardware settings (see section 4.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #14 • SIS-PMS-LAN is connected to local network (ping test is ok) but not responding. Reset SIS-PMS-LAN by pressing the Reset button (A) on the side control panel (see Figure #2 above) or switch it off and then on again (see Figure #1 above) NOTE: The Reset button A (see Figure #2 above) can sometimes help if SIS-PMS-LAN can’t be accessed or works abnormally. The device will then be restarted.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 5.2. Managing SIS-PMS-LAN After successful connection, close LAN devices window. You can now start managing SIS-PMS-LAN via the Power Manager interface. Double click on the socket icon in the system tray or select Open from the popup menu (see Figure #10 above). You will get the window of the main control panel shown on the Figure #15 below.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Sockets should switch on and off (green color means the socket is switched off; red color means the socket is switched on) when you double click on them. Click the Settings button for each socket to access the Settings dialog box (see Figure #16 below). Figure #16 You can choose a different device and another socket from the Device and Socket drop down list-boxes.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE • • • • • It is possible to give a name to the device and socket (for example Printer or Scanner) using the Rename button Check the System tray checkbox if you want to put the icon of the socket into the system tray. You can choose the icon from drop down list box. Such icon is a fast way to switch the device connected to the socket on/off or check the device status You can also assign a hot key to switch the socket on/off.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 6. Power Manager core features 6.1. Setting up the hardware schedule Using the Hardware schedule button available from the Settings window (see section 5.2 above) you can create the hardware timer schedule (see Figure #17 below). To add a new record, click the Add button.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE • The window Add entry will appear (see Figure #18 below). In the dialog box, specify the required time and the action Figure #18 • To edit the record, select it and click the Edit button or just double click on the entry (see Figure #17 above).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #19 • • To remove the record, select it and click the Remove button (see Figure #17 above). You can select multiple entries using Ctrl and Shift keys.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #20 • • After the schedule record has been created, click the Apply button (see Figure #17 above) to save the hardware timer schedule changes. In case of incorrect entries, these will be highlighted and an error message will appear. Click the Apply button again after correcting all the errors Use Sync button (see Figure #17 above) to synchronize device timer with PC clock.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE • • • • • • • The new event time should be in the future There can not be a duplicate entry The total quantity of events can not exceed 16 per socket The total quantity of events also depends on the total execution period of the schedule The interval between the present and the last entry can not exceed 180 days Without loop the total execution period of the schedule can not exceed 215 days Loop period can not exceed 180 days NOTE: The hardware
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE NOTE: the software timer schedule will only be executed if the managing computer is on and the Power Manager is launched. Figure #21 • To add a new task, click the Add button.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #22 In the Add task window, check Switch ON time and/or Switch OFF time checkboxes and specify the time to switch the socked on and/or off. If you want the same event to be performed periodically, check Perform task every checkbox and specify the time interval. You can also add remarks about the task in the Comment field. To disable the task, uncheck the Enabled checkbox and to enable the task again, re-check the checkbox.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE • To edit the task, select it (see Figure #21 above) and click the Edit button or just double click on the task. The Edit task window will appear (see Figure #23 below) Figure #23 • To remove the task select it and click the Remove button (see Figure #21 above).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Shift keys. You can also remove all tasks by clicking the Clear button HINT: Use the popup menu which can be activated by the right mouse button click over the table (see Figure #21 above). 6.3. Setting up application events Using the Application events window you can specify the socket events when a certain application is launched or closed down.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #24 • To add a new program event, click the Add app button.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #25 Specify the application title and path to it using the Browse (…) button or typing it manually in the Title and Path name fields. If you use the Browse (…) button you can also select a shortcut to the application. In this case the application title and path name will be taken automatically via the shortcut if possible. After you have specified the application, check On run and/or On exit and choose the event (switch on or off).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE NOTE: The On run event will take place when the first window of the selected application is opened. The On exit event will take place when the last window of the application is closed. HINT: Your device is an advanced standby-killer. Using this feature you can for example switch your scanner on/off whenever Photoshop is started/closed. • To add a new file event, click the Add folder button (see Figure #24 above).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Specify the path to the folder you would like to monitor using the Browse (…) button or typing it manually in the Path name field. Specify the File name mask using wildcard characters: *, ?. Check then On placing and/or On removal checkboxes and select the event and delay. NOTE: The On placing event will take place when the first file matching the specified file name mask is placed into the specified folder.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #27 • To remove the event, select it and click the Remove button (see Figure #24 above). You can select multiple events using Ctrl and Shift keys. You can also remove all events by clicking the Clear button HINT: Use the popup menu which can be activated by the right mouse button click over the table.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 7. Power Manager advanced features The following information is for advanced users which wish to have full access to the advanced features of SIS-PMS-LAN. Click the Advanced features button available from the Settings window (see section 5.2 above). The following window will then appear (see Figure #28 below).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 7.1. Processing the alarms Whenever the actual measured voltage on the manageable socket deviates from the status set by your switching tasks, it is called a Voltage alarm. The Voltage alarm can for example be caused by a blackout and will be resolved after power returns. The Voltage alarm can also be triggered if for any reason a switching task could not be carried out (switching malfunction).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE • • • Check the Disable alarm log window checkbox to disable the popup Alarm log window (applies to all devices) Check the When alarm goes on checkbox, then click the Browse(…) button to select the desired program to be launched whenever a voltage alarm is triggered Check the When alarm goes off checkbox, then click the Browse(…) button to select the desired program to be launched after the alarm status (see above) is resolved 7.2.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #30 Set the checkbox Share this device via network if you want to enable the network access to the device (via this PC). To prevent unauthorized access to the device enter the access password in the field Password. NOTE: The port 6100 should be open. Contact your LAN administrator for further details. To be able to use this shared SIS-PMS-LAN on a client PC choose Shared devices from the Main menu (see Figure #10 above).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #31 To add a new remote device, press the Add button. You will see the window Add network device (see Figure #32 below).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE Figure #32 Enter the network name of the server which is connected to SISPMS-LAN in the field Hostname. Enter the name of the target SIS-PMSLAN in the field Device name. Enter access password in the field Password. To disconnect from the device uncheck the option Enable, set this option on again to regain the access. To locate the shared device in your local network, click the button Find.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE device will appear. Choose the proper server and then the device and click OK button. To edit the network device, select it and click the Edit button, or just double click on the network device (see Figure #31 above). The Edit network device window will appear (see Figure #33 below).
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE • To remove the network device, select it and click the Remove button (see Figure #31 above). You can select multiple network devices using Ctrl and Shift keys. You can also remove all network devices by clicking the Clear button HINT: Use the popup menu which is available with the right mouse button click over the table. 7.3.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE For each of the connected devices the following information will then be provided and placed into Info.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE 8. Troubleshooting Problem The circuit breaker is activated (tripped). The switching command is not carried out, the rocker switch and indicators are not lit. The status of SIS-PMS-LAN in Power Manager does not become Connected SIS-PMS-LAN is connected to local network (ping test is ok) but not responding. Connection to SIS-PMS-LAN is lost. It seems something is wrong with its IP address.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE WARRANTY CONDITIONS The warranty period is 36 months and begins with the sale to the end user. The receipt must clearly list the date of purchase and the part number, in addition it should be printed. Keep the receipt for the entire warranty period since it is required for all warranty claims. During the warranty period the defective items will be credited, repaired or replaced at the manufacturer's expense.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE GARANTIE VOORWAARDEN CONDITIONS DE GARANTIE De garantietermijn bedraagt 36 maanden en gaat in op de aankoopdatum van het product door de eindgebruiker. Op de aankoopbon moeten de aankoopdatum en productomschrijving duidelijk vermeld staan. Gelieve de aankoopbon de gehele garantieperiode te bewaren, deze is ten alle tijden benodigd voor alle garantie aanspraken.
SIS-PMS-LAN PROGRAMMABLE SURGE PROTECTOR WITH LAN INTERFACE ГАРАНТИЙНЫЙ ТАЛОН 1. Гарантийное обслуживание предоставляется в течение срока гарантии, при наличии правильно и четко заполненного гарантийного талона, и изделия в полной комплектации. Серийный номер и модель изделия должны соответствовать указанным в гарантийном талоне. 2. Гарантийное обслуживание представляет собой бесплатное устранение всех неполадок (ремонт), или замену изделия на новое (аналогичное). 3.