EG-PM2 PROGRAMMABLE POWER OUTLET STRIP USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ КЕРІВНИЦТВО КОРИСТУВАЧА
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP PROGRAMMABLE POWER OUTLET STRIP PROGRAMMABLE POWER OUTLET STRIP PROGRAMMABLE POWER OUTLET STRIP BANDE PROGRAMMABLE PRISE DE COURANT ПРОГРАММИРУЕМЫЙ ЭЛЕКТРИЧЕСКИЙ УДЛИНИТЕЛЬ ПРОГРАМОВАНИЙ ЕЛЕКТРИЧНИЙ ПОДОВЖУВАЧ Do not plug several sockets in line Do not use if covered De-energized only if power plug is unplugged NEVER connect appliances which does not allow unattained operation ! 2 All brands and logos are registered trademarks of their respective owners
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP 1. Introduction Your EG-PM2 is an advanced power outlet strip with power management features. Four sockets are individually manageable by the computer via USB interface. The sockets can be switched on/off by a timer schedule, by user or different events. It is also possible to pre-program the unit event timer schedule (hardware schedule) and then disconnect EG-PM2 from the managing computer. The device can be used as an advanced standbykiller. 1.1.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP The manageable sockets can then be switched on and off by the schedule, simple typical applications could be: “switch my peripherals on every working day at 8:50 AM” etc. The manageable sockets can also be programmed with Power Manager software to react whenever a certain event occurs (Windows or other programs start-up/shutdown), simple typical applications could be: “switch my scanner on when I want to scan” or “switch my printer off whenever I exit Windows” 1.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP Net weight: 1.0 kg 1.3. Hardware requirements Computer running Windows® 2000/XP/Vista or Windows 7 / 8 is required for using the Power Manager software One free USB port 1.4.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP 2.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP 2.1. Indicators and switches Main rocker switch Z with built in self recovering fuse (see Figure #1 above) The indicator Socket 1 (2,3,4) (see Figure #1 above) is lit – this means that this particular socket is switched on The indicator Power (see Figure #1 above) is lit – this means that EG-PM2 is connected to the power supply and active 3. Installation It is strongly recommended to avoid damp or wet places for installation.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP 3.1. Getting started Connect EG-PM2 to the wall socket first and then to the USB socket of the manageable computer or vice versa. EG-PM2 can now be switched on and off by means of the Main rocker switch (Z). Two (the first and the last) sockets of EG-PM2 are switched on and off by means of the Main rocker switch (Z) and cannot be managed by the computer – so they are called non-manageable sockets in this manual.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP As soon as you turn the Main rocker switch (Z) on then the Power manager software or the hardware schedule will be able to turn the manageable sockets on and off. To protect the connected devices from possible high current and short circuit EG-PM2 is equipped with the automatic circuit breaker. NOTE: If the total power consumption (or peak power) of the devices, connected to EG-PM2 exceeds 2500 Watts, the circuit breaker may power EG-PM2 off.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP After a successful installation a socket icon system tray. will appear in your 4.1. Managing EG-PM2 Double click on the socket icon in the system tray or select Open from the popup menu, you will get the windows with device list (see Figure #2 below).
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP Push the Device settings button (bottom right here) to set the devicespecific options (see Figure #3 below) Figure #3 Double click on the device and you will get the window of the main control panel shown on the Figure #4 below.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP Figure #4 Double click over each socket will switch it on and off (green color means the socket is switched off; red color means the socket is switched 12 All brands and logos are registered trademarks of their respective owners
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP on). Click the Settings button for each socket to access the Settings dialog box (see Figure #5 below). Figure #5 You can choose a different device and another socket from the Device and Socket drop down list-boxes.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP It is possible to give a name to the device and socket (for example Printer or Scanner) using the Rename button Check the System tray checkbox if you want to put the icon of the socket into the system tray. You can choose the icon from drop down list box. Such icon is a fast way to switch the device connected to the socket on/off or check the device status You can also assign a hot key to switch the socket on/off.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP 4.2. Setting up the hardware schedule Using the Hardware schedule button available from the Settings window you can create the hardware timer schedule (see Figure #6 below). To add a new record, click the Add button.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP The window Add entry will appear (see Figure #7 below). In the dialog box, specify the required time and the action Figure #7 To edit the record, select it and click the Edit button or just double click on the entry.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP Figure #8 To remove the record, select it and click the Remove button (see Figure #6 above). You can select multiple entries using Ctrl and Shift keys.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP Figure #9 After the schedule record has been created, click the Apply button (see Figure #6 above) to save the hardware timer schedule changes. In case of incorrect entries, these will be highlighted and an error message will appear. Click the Apply button again after correcting all the errors Use Sync button (see Figure #6 above) to synchronize device timer with PC clock.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP The new event time should be in the future There can not be a duplicate entry The total quantity of events can not exceed 16 per socket The total quantity of events also depends on the total execution period of the schedule The interval between the present and the last entry can not exceed 180 days Without loop the total execution period of the schedule can not exceed 215 days Loop period can not exceed 180 days NOTE: If the device is powered off the ha
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP 4.3. Setting up the software schedule Using the Software schedule button available from the Settings window you can create the software timer schedule (see Figure #10 below). NOTE: the software timer schedule will only be executed if the managing computer is on and the Power Manager is launched.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP To add a new task, click the Add button. The Add task window will appear (see Figure #11 below) Figure #11 In the Add task window, check Switch ON time and/or Switch OFF time checkboxes and specify the time to switch the socked on and/or off. If you want the same event to be performed periodically, check Perform task every checkbox and specify the time interval. You can also add remarks about the task in the Comment field.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP uncheck the Enabled checkbox and to enable the task again, re-check the checkbox. To edit the task, select it (see Figure #10 above) and click the Edit button or just double click on the task.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP To remove the task select it and click the Remove button (see Figure #9 above). You may select multiple tasks using Ctrl and Shift keys. You can also remove all tasks by clicking the Clear button HINT: Use the popup menu which can be activated by the right mouse button click over the table (see Figure #10 above). 4.4.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP Figure #13 To add a new program event, click the Add app button.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP Figure #14 Specify the application title and path to it using the Browse (…) button or typing it manually in the Title and Path name fields. If you use the Browse (…) button you can also select a shortcut to the application.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP via the shortcut if possible. After you have specified the application, check On run and/or On exit and choose the event (switch on or off). NOTE: The On run event will take place when the first window of the selected application is opened. The On exit event will take place when the last window of the application is closed. HINT: Your device is an advanced standby-killer.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP Figure #15 Specify the path to the folder you would like to monitor using the Browse (…) button or typing it manually in the Path name field. Specify the File name mask using wildcard characters: *, ?. Check then On placing and/or On removal checkboxes and select the event and delay. NOTE: The On placing event will take place when the first file matching the specified file name mask is placed into the specified folder.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP HINT: Your device is an advanced standby-killer. Use the Add folder button to assign c:\\system32\\spool\\printers folder to switch your printer on whenever you start printing and to switch it off again whenever you are ready with printing. HINT: If you have several printers connected to the same computer, we suggest moving default spool directory of each printer to a separate location.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP Figure #16 To remove the event, select it and click the Remove button (see Figure #13 above). You can select multiple events using Ctrl and Shift keys. You can also remove all events by clicking the Clear button HINT: Use the popup menu which can be activated by the right mouse button click over the table.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP 5. Managing EG-PM2 via your own software To let you switch the sockets from your own applications the following command line interface syntax is supported: pm.exe -[on | off] -device name -socket name Examples: "C:\Program Files\Energenie\Power Manager\pm.exe" -on -EG-PM Socket1 "E:\Utils\PM3\pm.exe" -off -My EG-PM -Table lamp Execute pm.exe with -info key (pm.exe –info) to get the complete information about the status of the current devices.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP NOTE: Each use of this command line option totally overrides the data in Info.ini file. NOTE: Power Manager should be active.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP 6. Troubleshooting Problem The rocker switch turns off. The switching command is not carried out and indicators are not lit. Software reports "Device I/O request error" after switching Timer schedule is delayed Solution The load connected to the device is too high, some of the devices connected to the EG-PM2-LAN should be disconnected before the rocker switch can be turned on. There is no power supply to the EG-PM2.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP 33 All brands and logos are registered trademarks of their respective owners
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP Waste disposal: Entsorgungshinweise: Do not deposit this equipment with the household waste. Improper disposal can harm both the environment and human health. For Information about waste collection facilities for used electrical and electronic devices, please contact your city council or an authorized company for the disposal of electrical and electronic equipment. Werfen Sie dieses Gerät nicht in den Hausmüll.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP WARRANTY CONDITIONS The warranty period is 24 months and begins with the sale to the end user. The receipt must clearly list the date of purchase and the part number, in addition it should be printed. Keep the receipt for the entire warranty period since it is required for all warranty claims. During the warranty period the defective items will be credited, repaired or replaced at the manufacturer's expense.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP GARANTIE VOORWAARDEN CONDITIONS DE GARANTIE De garantietermijn bedraagt 24 maanden en gaat in op de aankoopdatum van het product door de eindgebruiker. Op de aankoopbon moeten de aankoopdatum en productomschrijving duidelijk vermeld staan. Gelieve de aankoopbon de gehele garantieperiode te bewaren, deze is ten alle tijden benodigd voor alle garantie aanspraken. Tijdens de garantieperiode zullen alle gebreken verholpen of vervangen worden door de fabrikant d.m.v.
EG-PM2 PROGRAMMABLE POWER OUTLET STRIP ГАРАНТИЙНЫЙ ТАЛОН 1. Гарантийное обслуживание предоставляется в течение срока гарантии, при наличии правильно и четко заполненного гарантийного талона, и изделия в полной комплектации. Серийный номер и модель изделия должны соответствовать указанным в гарантийном талоне. 2. Гарантийное обслуживание представляет собой бесплатное устранение всех неполадок (ремонт), или замену изделия на новое (аналогичное). 3.