EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ КЕРІВНИЦТВО КОРИСТУВАЧА
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE PROGRAMMIERBARE STECKDOSENLEISTE MIT LAN-ANSCHLUSS PROGRAMMEERBARE STEKKERDOOS MET LAN INTERFACE BOÎTIER COMMANDÉ À DISTANCE ET PROGRAMMABLE AVEC PRISE LAN ПРОГРАММИРУЕМЫЙ ЭЛЕКТРИЧЕСКИЙ УДЛИНИТЕЛЬ С ИНТЕРФЕЙСОМ К ЛОКАЛЬНОЙ КОМПЬЮТЕРНОЙ СЕТИ EЛЕКТРИЧНИЙ ПОДОВЖУВАЧ, ЩО ПРОГРАМУЄТЬСЯ З LAN ЫНТЕРФЕЙСОМ Do not plug several sockets in line Do not use if covered De-energized only if power plug
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 1. Introduction Your EG-PM2-LAN is an advanced power outlet strip with power management features. Four sockets are individually manageable via the LAN interface. The sockets can be switched on/off by a timer schedule, by user or different events. It is also possible to pre-program the unit event timer schedule (hardware schedule) and then disconnect EG-PM2-LAN from LAN and use it elsewhere. The device can be used as an advanced standby-killer.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE It is also possible to assign an external IP-address to EG-PM2-LAN, to enable worldwide remote access via the Internet No external IP-address at home? No problem. Create your own user account on EnerGenie.com to manage your EG-PM2-LAN via Internet with any PC or smartphone. Switching on your coffee maker before setting off for home becomes a reality.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Timer accuracy: not more than 2 seconds error per day in case that power is always present. Otherwise there can be an additional up to 2 seconds error per each "power off" Indoor use Net weight: 1 Kg 1.3.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 2.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #2 Indicator Schedule Reset Button (A) Master Switch Button (B) LAN socket with LAN activity indicators IP Config Button (C) 7 All brands and logos are registered trademarks of their respective owners
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #3 Power On / Reset (after power consumption exceeds 2500 Watts) Power cord Off Main rocker switch (Z) with power indicator and self recovering fuse 8 All brands and logos are registered trademarks of their respective owners
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 2.1.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 3. Installation It is strongly recommended to avoid damp or wet places for installation. EG-PM2-LAN should be connected to the European AC wall socket of the standard DIN 49 440. Do not plug several sockets in line. Do not use if covered. De-energized only if power plug is unplugged. NEVER connect appliances which do not allow unattained operation! 3.1.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE The sockets: Socket 1, Socket 2, Socket 3 and Socket 4 can be managed or pre-programmed by computer via LAN. They are called manageable sockets in this manual. The manageable sockets of EG-PM2-LAN can be programmed to be on or off. The current status of each manageable socket is represented by the corresponding indicator which will be lit if socket has power to it.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE the excessive load first and then (after 2-3 minutes) press the main rocker switch (Z) to restore the power supply (see Figure #3 above). To be able to use EG-PM2-LAN you will now have to complete its LAN configuration. 3.2. Preparing LAN configuration of EG-PM2-LAN Before configuring EG-PM2-LAN hardware settings, please, let it obtain its IP address.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE If you choose for option B then the following procedure is required to let EG-PM2-LAN obtain a fixed IP address: Turn EG-PM2-LAN on (with the Main rocker switch Z) Press IP Config (C) button on the side control panel (see Figure #2 above) with the tip of a pen While holding it pressed, press and release Reset (A) button and wait for about 3 seconds until you hear the sockets switching twice The above-mentioned procedure forces EG-PM2-LAN
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 3.3. Power Manager installation It is now time to identify which IP address has been obtained by EGPM2-LAN. We need to carry out the following: Insert the Power Manager CD into a PC CD-ROM drive. This PC can be connected either to the same LAN where the device is (if you chose option A section 3.2) or directly to the device with the crossover RJ-45 cable (if you chose option B section 3.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 3.4. IP configuration The utility Find EG-PM2-LAN (see Figure #4 below) will run automatically during the software installation but it can also be started from Start/All Programs/Gembird/Power Manager. The IP range where you would like to search for EG-PM2-LAN will be set automatically according to the IP settings of your LAN adapter but can be changed manually in the Adapter subnet fields. Now press the Search button.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #4 The window of your default internet browser will be then opened to give you access to the built-in web-server. See section 4 below for the further details.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 4. The web server Your EG-PM2-LAN is equipped with a web-server which allows managing the device using any web browser such as Internet Explorer etc. 4.1. Web-server login page To access the web server of EG-PM2-LAN, just open Internet Explorer (or other browser) and input the IP address of EG-PM2-LAN (for example http://192.168.1.241).
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE After a successful login you will face the Socket 1 Status page (see section 4.2 below). NOTE: There is a possibility that you might then need to open the LAN settings page (see section 4.5 below) to complete the IP configuration. 4.2. EnerGenie page With the help of EnerGenie page (see Figure #6 below) you will be able to see the status of all your four manageable sockets, and to switch the sockets on and off manually.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Register the device. To restrict access to the device via the Internet to the rightful owner only, the device should be registered – e.g. assigned to your account. To register the device, simply push the button Register on this page (see Figure #6 below). You will then be redirected to Login page of EnerGenie.com. If you already own an account at EnerGenie.com then just enter your login and password on this page and you are done.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure # 6 20 All brands and logos are registered trademarks of their respective owners
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE After a successful registration and activation the button Register will be renamed to Login (and will then open the Login page of EnerGenie.com) and the button Activate will turn into Deactivate. If by any reason you would eventually decide to stop managing your EGPM2-LAN from Internet use then Deactivate button to stop communication of the device with EnerGenie.com server.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #7 The socket shown on the Figure #7 is currently off, it will be turned on again automatically on the 9th of July at 14:40:30 and on the same day at 14:50:45 it will be switched off. Next day it will be turned on at 14:20:00 and at 14:30:15 it will be switched off. Last two events will be th executed each day staring from the 10 of July.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Below the page you can see the current time of the web-server and eventual information about the last successful timer synchronization. Automatic timer synchronization is used if Use NTP for timer correction option is enabled (see section 4.6 below). NOTE: If a certain socket has a switching fault, e.g.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #8 Choose the date and time of the scheduled event. If you wish the event to be executed periodically then choose Periodic option and set the loop period. To commit to your changes press the Apply button. To delete the entry press the x button. To delete the entered schedule press the Clear schedule button.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE NOTE: The hardware schedule keeps running even when the device is powered off. However it is recommended not to power off the device for longer than 1 week, because the built-in battery might get discharged then. In this case the internal clock of the device would be reset and as result some schedule events would not be executed. Besides all the sockets would lose their previous status (they will be switched on).
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #9 26 All brands and logos are registered trademarks of their respective owners
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 4.5.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE On the LAN settings page (see Figure #10 above) you can set up DHCP, IP address, Subnet mask, Gateway, DNS server and IP filter (up to 3 IP addresses can then be enabled for remote access). The new settings will be applied immediately after you press the Apply button. IP address, Subnet mask, Gateway, DNS server will be used only if the DHCP option is disabled.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 4.6. Device settings page On the device settings page you can setup name, password and internal time of EG-PM2-LAN (see Figure #11 below).
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE To be able to setup the schedule of EG-PM2-LAN you have to first setup its internal clock correctly. Enter the current local time and date. Alternatively if the option Use NTP for timer correction is enabled (by default) then the time will be taken from NTP server. The device will try to connect with the server every 18 hours. The first synchronization would take place in 15 seconds after you press the Apply button.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Don’t forget to push the Apply button to save your settings. 4.7. Web-server logout Having finished working with EG-PM2-LAN, choose Log Out in the main menu. If you don’t do this, you will be logged automatically after 10 minutes of inactivity. While you are logged to the web server, it can’t be accessed from any other computer.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 5. EnerGenie.com device interface With your free personal account at EnerGenie.com website you will be able to access your EG-PM2-LAN from anywhere in the world using any Internet-enabled device (desktop PC, laptop, smartphone etc). See section 4.2 above on how to register your EG-PM2-LAN on the server and setup the connection. 5.1. Logging in To login into your EnerGenie account just open the webpage www.energenie.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Check Remember me checkbox for automatic login in the future (the website will then save a cookie on your computer). If you lost your password, click Forgot password button. 5.2. Device management page After a successful login you will see the list of your registered devices and their corresponding sockets (see Figure # 13 below).
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE This page will automatically update itself and will keep showing you the time when your device was last seen online (the latest time when the device communicated with the server) and the status of each socket. Click your user name to change your account settings. Click the device to change its name and/or transfer it to another account. Click the sockets to change their names Click the On/Off buttons to switch the sockets on or off.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 6. Power Manager software The Power Manager software is designed to support not only EGPM2-LAN but also other power management family products (please visit www.energenie.com) . 6.1. Finding EG-PM2-LAN To be able to manage preconfigured EG-PM2-LANs, please, do the following: Install Power Manager software on a PC connected to your local network.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #14 Please select Device – Add Device, or press [Ctrl+A] (see menu on Figure #15 below) 36 All brands and logos are registered trademarks of their respective owners
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #15 In the Add LAN device window (see figure #16 below) please, enter correct IP address, port number (5000 by default) and password (1 by default) as configured on the Device settings page (see section 4.6 above) of the web server. To disconnect from the device uncheck the option Enable, set this option again to regain the access. Click OK button to return to the LAN devices window.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #16 Specified device should then appear with a green square next to it and Connected status in the LAN devices window (see Figure #17 below).
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #17 To edit the LAN device, select it and click the Edit button, or just double click on the LAN device 39 All brands and logos are registered trademarks of their respective owners
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE To remove the LAN device, select it and click the Remove button. You can select multiple LAN devices using Ctrl and Shift keys. You can also remove all LAN devices by clicking the Clear button HINT: Use the popup menu which can be activated by the right mouse button click over the table.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #18 EG-PM2-LAN is connected to local network (ping test is ok) but not responding. Reset EG-PM2-LAN by pressing the Reset button (A) on the side control panel (see Figure #2 above) or switch it off and then on again (see Figure #1 above) NOTE: The Reset button A (see Figure #2 above) can sometimes help if EG-PM2-LAN can’t be accessed or works abnormally. The device will then be restarted.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 6.2. Managing EG-PM2-LAN After successful connection, close LAN devices window. You can now start managing EG-PM2-LAN via the Power Manager interface. Double click on the socket icon in the system tray or select Open from the popup menu (see Figure #14 above). You will get the window of the main control panel shown on the Figure #19 below.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Sockets should switch on and off (green color means the socket is switched on; red color means the socket is switched off) when you double click on them. Click the Settings button for each socket to access the Settings dialog box (see Figure #20 below). Figure #20 You can choose a different device and another socket from the Device and Socket drop down list-boxes.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE It is possible to give a name to the device and socket (for example Printer or Scanner) using the Rename button Check the System tray checkbox if you want to put the icon of the socket into the system tray. You can choose the icon from drop down list box. Such icon is a fast way to switch the device connected to the socket on/off or check the device status You can also assign a hot key to switch the socket on/off.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 7. Power Manager core features 7.1. Setting up the hardware schedule Using the Hardware schedule button available from the Settings window (see section 6.2 above) you can create the hardware timer schedule (see Figure #21 below). To add a new record, click the Add button.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE The window Add entry will appear (see Figure #22 below). In the dialog box, specify the required time and the action Figure #22 To edit the record, select it and click the Edit button or just double click on the entry (see Figure #21 above). The same window will appear (see Figure #22 above) To remove the record, select it and click the Remove button (see Figure #21 above). You can select multiple entries using Ctrl and Shift keys.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #21 above) and specify the loop time period in the Edit loop period window (see Figure #23 below) Figure #23 After the schedule record has been created, click the Apply button (see Figure #21 above) to save the hardware timer schedule changes. In case of incorrect entries, these will be highlighted and an error message will appear.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE NOTE: The hardware schedule keeps running even when the device is powered off. However it is recommended not to power off the device for longer than 1 week, because the built-in battery might get discharged then. In this case the internal clock of the device would be reset and as result some schedule events would not be executed. Besides all the sockets would lose their previous status (they will be switched on).
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #24 To add a new task, click the Add button.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #25 In the Add task window, check Switch ON time and/or Switch OFF time checkboxes and specify the time to switch the socked on and/or off. If you want the same event to be performed periodically, check Perform task every checkbox and specify the time interval. You can also add remarks about the task in the Comment field. To disable the task, uncheck the Enabled checkbox and to enable the task again, re-check the checkbox.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE To edit the task, select it (see Figure #24 above) and click the Edit button or just double click on the task. The Edit task window will appear (see Figure #26 below) Figure #26 To remove the task select it and click the Remove button (see Figure #24 above).
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Shift keys. You can also remove all tasks by clicking the Clear button HINT: Use the popup menu which can be activated by the right mouse button click over the table (see Figure #24 above). 7.3. Setting up application events Using the Application events window you can specify the socket events when a certain application is launched or closed down.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #27 To add a new program event, click the Add app button.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #28 Specify the application title and path to it using the Browse (…) button or typing it manually in the Title and Path name fields. If you use the Browse (…) button you can also select a shortcut to the application. In this case the application title and path name will be taken automatically via the shortcut if possible. After you have specified the application, check On run and/or On exit and choose the event (switch on or off).
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE NOTE: The On run event will take place when the first window of the selected application is opened. The On exit event will take place when the last window of the application is closed. HINT: Your device is an advanced standby-killer. Using this feature you can for example switch your scanner on/off whenever Photoshop is started/closed. To add a new file event, click the Add folder button (see Figure #27 above).
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Specify the path to the folder you would like to monitor using the Browse (…) button or typing it manually in the Path name field. Specify the File name mask using wildcard characters: *, ?. Check then On placing and/or On removal checkboxes and select the event and delay. NOTE: The On placing event will take place when the first file matching the specified file name mask is placed into the specified folder.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Figure #30 To remove the event, select it and click the Remove button (see Figure #27 above). You can select multiple events using Ctrl and Shift keys. You can also remove all events by clicking the Clear button HINT: Use the popup menu which can be activated by the right mouse button click over the table.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 8. Managing EG-PM2-LAN via your own software To let you switch the sockets from your own applications the following command line interface syntax is supported: pm.exe -[on | off] -device name -socket name Examples: "C:\Program Files\ Energenie\Power Manager\pm.exe" -on -My EnerGenie -Socket1 "E:\Utils\PM3\pm.exe" -off -My EnerGenie -Table lamp Execute pm.exe with -info key (pm.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Socket#SwitchState, where # is replaced by a certain socket number - TRUE, when the socket is switched on, FALSE, when the socket is switched off Socket#VoltageState, where # is replaced by a certain socket number - TRUE, when voltage presence on the socket is detected, FALSE, when there is no voltage on the socket; Example: NOTE: Each use of this command line option totally overrides the data in Info.ini file.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 10. Troubleshooting Problem The rocker switch turns off. The switching command is not carried out, the rocker switch and indicators are not lit. The status of EG-PM2-LAN in Power Manager does not become Connected EG-PM2-LAN is connected to local network (ping test is ok) but not responding. Connection to EG-PM2-LAN is lost. It seems something is wrong with its IP address.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE 61 All brands and logos are registered trademarks of their respective owners
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE Waste disposal: Entsorgungshinweise: Do not deposit this equipment with the household waste. Improper disposal can harm both the environment and human health. For Information about waste collection facilities for used electrical and electronic devices, please contact your city council or an authorized company for the disposal of electrical and electronic equipment. Werfen Sie dieses Gerät nicht in den Hausmüll.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE WARRANTY CONDITIONS The warranty period is 24 months and begins with the sale to the end user. The receipt must clearly list the date of purchase and the part number, in addition it should be printed. Keep the receipt for the entire warranty period since it is required for all warranty claims. During the warranty period the defective items will be credited, repaired or replaced at the manufacturer's expense.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE GARANTIE VOORWAARDEN CONDITIONS DE GARANTIE De garantietermijn bedraagt 24 maanden en gaat in op de aankoopdatum van het product door de eindgebruiker. Op de aankoopbon moeten de aankoopdatum en productomschrijving duidelijk vermeld staan. Gelieve de aankoopbon de gehele garantieperiode te bewaren, deze is ten alle tijden benodigd voor alle garantie aanspraken.
EG-PM2-LAN PROGRAMMABLE POWER OUTLET STRIP WITH LAN INTERFACE ГАРАНТИЙНЫЙ ТАЛОН 1. Гарантийное обслуживание предоставляется в течение срока гарантии, при наличии правильно и четко заполненного гарантийного талона, и изделия в полной комплектации. Серийный номер и модель изделия должны соответствовать указанным в гарантийном талоне. 2. Гарантийное обслуживание представляет собой бесплатное устранение всех неполадок (ремонт), или замену изделия на новое (аналогичное). 3.