User's Manual
Table Of Contents
- Document History
- Introduction
- Product Concept
- Application Interface
- Operating Modes
- Power Supply
- Power Up / Power Down Scenarios
- Automatic GPRS Multislot Class Change
- Charging Control
- Summary of State Transitions (Except SLEEP Mode)
- RTC Backup
- SIM Interface
- Serial Interface ASC0
- Serial Interface ASC1
- USB Interface
- I2C Interface
- Audio Interfaces
- Control Signals
- Antenna Interface
- Electrical, Reliability and Radio Characteristics
- Mechanics
- Sample Application
- Reference Approval
- Appendix
TC63 Hardware Interface Description
Strictly confidential / Draft
s
TC63_HD_V00.432 Page 79 of 97 11.05.2005
5.6 Reliability Characteristics
The test conditions stated below are an extract of the complete test specifications.
Table 22: Summary of reliability test conditions
Type of test Conditions Standard
Vibration Frequency range: 10-20Hz; acceleration: 3.1mm
amplitude
Frequency range: 20-500Hz; acceleration: 5g
Duration: 2h per axis = 10 cycles; 3 axes
DIN IEC 68-2-6
Shock half-sinus Acceleration: 500g
Shock duration: 1msec
1 shock per axis
6 positions (± x, y and z)
DIN IEC 68-2-27
Dry heat Temperature: +70 ±2°C
Test duration: 16h
Humidity in the test chamber: < 50%
EN 60068-2-2 Bb ETS
300019-2-7
Temperature
change (shock)
Low temperature: -40°C ±2°C
High temperature: +85°C ±2°C
Changeover time: < 30s (dual chamber system)
Test duration: 1h
Number of repetitions: 100
DIN IEC 68-2-14 Na
ETS 300019-2-7
Damp heat cyclic High temperature: +55°C ±2°C
Low temperature: +25°C ±2°C
Humidity: 93% ±3%
Number of repetitions: 6
Test duration: 12h + 12h
DIN IEC 68-2-30 Db
ETS 300019-2-5
Cold (constant
exposure)
Temperature: -40 ±2°C
Test duration: 16h
DIN IEC 68-2-1