6.4 Reliability Characteristics
6.4
Reliability Characteristics
The test conditions stated below are an extract of the complete test specifications.
Table 20: Summary of reliability test conditions
Type of test Conditions Standard
Vibration Frequency range: 10-20Hz; acceleration: 5g
Frequency range: 20-500Hz; acceleration: 20g
Duration: 20h per axis; 3 axes
DIN IEC 60068-2-6
1
Shock half-sinus
Acceleration: 500g
Shock duration: 1msec
1 shock per axis
6 positions (± x, y and z)
DIN IEC 60068-2-27
Dry heat
Temperature: +70 ±2×C
Test duration: 16h
Humidity in the test chamber: < 50%
EN 60068-2-2 Bb
ETS 300 019-2-7
Temperature
change (shock)
Low temperature: -40×C ±2×C
High temperature: +85×C ±2×C
Changeover time: < 30s (dual chamber system)
Test duration: 1h
Number of repetitions: 100
DIN IEC 60068-2-14 Na
ETS 300 019-2-7
Damp heat cyclic
High temperature: +55×C ±2×C
Low temperature: +25×C ±2×C
Humidity: 93% ±3%
Number of repetitions: 6
Test duration: 12h + 12h
DIN IEC 60068-2-30 Db
ETS 300 019-2-5
Cold (constant
exposure)
Temperature: -40 ±2×C
Test duration: 16h
DIN IEC 60068-2-1
1.
For reliability tests in the frequency range 20-500Hz the Standard’s acceleration reference value was inc-
reased to 20g.
6.5
Pad Assignment and Signal Description
The SMT application interface on the PCS3 provides connecting pads to integrate the module
into external applications. The following Table 21 lists the pads’ assignments, Figure 32 (bot-
tom view) and Figure 33 (top view) show the connecting pads’ numbering plan.
Please note that a number of connecting pads are marked as reserved for future use (rfu) or
ground (GND) and further qualified as either (dnu), (GND) or (nc):
Pads marked "rfu" and qualified as "dnu" (do not use) may be soldered but should not be
connected to an external application.
Pads marked "rfu" and qualified as "GND" (ground) are assigned to ground with PCS3 mod-
ules, but may have different assignments with future Cinterion products using the same pad
layout.
Pads marked "GND" and qualified as "nc" (not connected) are internally not connected with
PCS3 modules but may be soldered and arbitrarily be connected to external ground.
Because with surface mount modules the heat is transported through the solder pads to the
external application’s PCB, it is generally recommended to solder all pads.