PCS3 Hardware Interface Description
3.3 Power-Up / Power-Down Scenarios
3.3.7
Turn off PCS3 in Case of Emergency
Caution: Use the EMERG_OFF line only when, due to serious problems, the software is not
responding for more than 5 seconds. Pulling the EMERG_OFF line causes the loss of all
information stored in the volatile memory. Therefore, this procedure is intended only for use in
case
of emergency, e.g. if PCS3 does not respond, if reset or shutdown via AT command fails.
The EMERG_OFF line is available on the application interface and can be used to switch off
the module. To control the EMERG_OFF line it is recommended to use an open drain / collector
driver.
To switch off, the EMERG_OFF line must be pulled to ground for longer than 40ms. After the
40ms and an additional delay period of 500ms the module shuts down as shown in Figure 7.
BATT+
Shut Down
PWR_IND
EMERG_OFF >40ms
VEXT
40ms
500ms
Figure 7: Shutdown by EMERG_OFF signal
Please note that the power supply voltage (BATT+) may be disconnected resp. switched off
only after having reached Shut Down as indicated by the PWR_IND signal going high. The
power supply has to be available (again) before the module is restarted.