PCS3 Hardware Interface Description
3.3 Power-Up / Power-Down Scenarios
3.3.5
Automatic Shutdown
Automatic shutdown takes effect if:
The PCS3 board is exceeding the critical limits of overtemperature or undertemperature
Undervoltage or overvoltage is detected
The automatic shutdown procedure is equivalent to the power down initiated with the AT^SMSO
command, i.e. PCS3 logs off from the network and the software enters a secure state avoiding
loss of data.
Alert messages transmitted before the device switches off are implemented as Unsolicited Re-
sult Codes (URCs). The presentation of the temperature URCs can be enabled or disabled with
the AT commands AT^SCTM. The URC presentation mode varies with the condition, please
see Section 3.3.5.1 to Section 3.3.5.3 for details. For further instructions on AT commands refer
to [1].