PCS3 Hardware Interface Description
3.3 Power-Up / Power-Down Scenarios
3.3.4
Configuring the IGT Line for Use as ON/OFF Switch
The IGT line can be configured for use in two different switching modes: You can set the IGT
line to switch on the module only, or to switch it on and off. The switching mode is determined
by the parameter "MEShutdown/OnIgnition" of the AT^SCFG command. This approach is use-
ful for application manufacturers who wish to have an ON/OFF switch installed on the host de-
vice.
By factory default, the ON/OFF switch mode of IGT is disabled:
at^scfg=meshutdown/onignition
^SCFG: "MEShutdown/OnIgnition","off"
OK
# Query the current status of IGT.
# IGT can be used only to switch on PCS3.
IGT works as described in Section 3.3.1.
To configure IGT for use as ON/OFF switch:
at^scfg=meshutdown/onignition
^SCFG: "MEShutdown/OnIgnition","on"
OK
# Enable the ON/OFF switch mode of IGT.
# IGT can be used to switch on and off PCS3.
We strongly recommend taking great care before changing the switching mode of the IGT line.
To ensure that the IGT line works properly as ON/OFF switch it is of vital importance that the
following conditions are met.
Switch-on condition: If the PCS3 is off, the IGT line must be asserted for at least 100ms before
being released.
Switch-off condition: If the PCS3 is on, the IGT line must be asserted for at least 2.1s before
being released. The module switches off after the line is released. The
switch-off routine is identical with the procedure initiated by AT^SMSO, i.e.
the software performs an orderly shutdown as described in Section 3.3.3.
Before switching off the module wait at least 5 seconds after startup.
Figure 6: Timing of IGT if used as ON/OFF switch