User's Manual Part 1

MC75 Hardware Interface Description
Strictly confidential / Draft
s
MC75_V00.190a Page 29 of 91 15.02.2005
VEXT
See note 1
TXD0/TXD1/RTS0/RTS1/DTR0 (driven by the application)
Serial interfaces
ASC0 and ASC1
Undefined
Active
PWR_IND
CTS0/CTS1/DSR0/DTR0
Figure 7: Signal states during turn-off procedure
Note 1: Depending on capacitance load from host application
3.2.2.2 Leakage Current in Power Down Mode
The leakage current in Power Down mode varies depending on the following conditions:
If the supply voltage at BATT+ was disconnected and then applied again without starting
up the MC75 module, the leakage current ranges between 90µA and 100µA.
If the MC75 module is started and afterwards powered down with AT^SMSO, then the
leakage current is only 50µA.
Therefore, in order to minimize the leakage current take care to start up the module at least
once before it is powered down.