User's Manual Part 1
MC75 Hardware Interface Description
Strictly confidential / Draft
s
MC75_V00.190a Page 23 of 91 15.02.2005
3.1.2 Measuring the Supply Voltage V
BATT+
The reference points for measuring the supply voltage V
BATT+
on the module are BATT+ and
GND, both accessible at a capacitor located close to the board-to-board connector of the
module.
Figure 4: Position of the reference points BATT+ and GND
3.1.3 Monitoring Power Supply by AT Command
To monitor the supply voltage you can also use the AT^SBV command which returns the
value related to the reference points BATT+ and GND.
The module continuously measures the voltage at intervals depending on the operating
mode of the RF interface. The duration of measuring ranges from 0.5s in TALK/DATA mode
to 50s when MC75 is in IDLE mode or Limited Service (deregistered). The displayed voltage
(in mV) is averaged over the last measuring period before the AT^SBV command was
executed.
Reference
point
BATT+
Reference
point GND