GWM300 Hardware Interface Overview Version: DocId: 01 GWM300_HIO_v01 M2M.GEMALTO.
GWM300 Hardware Interface Overview Page 2 of 35 2 Document Name: GWM300 Hardware Interface Overview Version: 01 Date: 2016-01-26 DocId: GWM300_HIO_v01 Status Confidential / Released GENERAL NOTE THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMENTATION (THE "PRODUCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CONTAINS INFORMATION ON GEMALTO M2M PRODUCTS.
GWM300 Hardware Interface Overview Page 3 of 35 Contents 124 Contents 0 Document History ...................................................................................................... 6 1 Introduction ................................................................................................................. 7 1.1 Related Documents ........................................................................................... 8 1.2 Terms and Abbreviations .....................................
GWM300 Hardware Interface Overview Page 4 of 35 Tables 4 Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Table 8: Table 9: Table 10: Table 11: Table 12: Terms and abbreviations................................................................................... 8 Directives ........................................................................................................ 10 Standards of North American type approval ...................................................
GWM300 Hardware Interface Overview Page 5 of 35 Figures 5 Figures Figure 1: Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Sample GWM300 labels ................................................................................. 15 GWM300 interfaces ........................................................................................ 19 Block diagram .................................................................................................
GWM300 Hardware Interface Overview Page 6 of 35 0 Document History 6 0 Document History New document: "Cinterion® GWM300 Hardware Interface Overview" Version 01 Chapter What is new -- Initial document setup.
GWM300 Hardware Interface Overview Page 7 of 35 1 Introduction 15 1 Introduction This document1 describes the hardware of the GWM300. The GWM300 contains a Cinterion® EHS6 module, and has an RS-232 compatible interface with an 8-pin Molex Microfit connector, including power supply, and an RF antenna connector. The scope of this document includes interface specifications, electrical as well as mechanical characteristics of the GWM300.
GWM300 Hardware Interface Overview Page 8 of 35 1.1 Related Documents 15 1.1 [1] [2] Related Documents AT Command Set for the Cinterion® EHS6 module Release Notes for the Cinterion® EHS6 module To visit the Gemalto M2M GmbH Website please use the following link: http://m2m.gemalto.com 1.
GWM300 Hardware Interface Overview Page 9 of 35 1.
GWM300 Hardware Interface Overview Page 10 of 35 1.3 Regulatory and Type Approval Information 15 1.3 Regulatory and Type Approval Information 1.3.1 Directives and Standards EHS6 has been designed to comply with the directives and standards listed below.
GWM300 Hardware Interface Overview Page 11 of 35 1.3 Regulatory and Type Approval Information 15 Table 4: Standards of European type approval ETSI EN 301 489-1 V1.9.2 Candidate Harmonized European Standard (Telecommunications series) Electro Magnetic Compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common Technical Requirements ETSI EN 301 489-7 V1.3.
GWM300 Hardware Interface Overview Page 12 of 35 1.3 Regulatory and Type Approval Information 15 Table 6: Standards of the Ministry of Information Industry of the People’s Republic of China SJ/T 11363-2006 “Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products” (2006-06). SJ/T 11364-2006 “Marking for Control of Pollution Caused by Electronic Information Products” (2006-06).
GWM300 Hardware Interface Overview Page 13 of 35 1.3 Regulatory and Type Approval Information 15 1.3.2 Safety Precautions The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating GWM300. Manufacturers of the cellular terminal are advised to convey the following safety information to users and operating personnel and incorporate these guidelines into all manuals supplied with the product.
GWM300 Hardware Interface Overview Page 14 of 35 1.3 Regulatory and Type Approval Information 15 IMPORTANT! Cellular terminals or mobiles operate using radio signals and cellular networks. In that case connections cannot be guaranteed at all times under all conditions. Therefore, you should never rely solely upon any wireless device for essential communications, for example emergency calls.
Page 15 of 35 GWM300 Hardware Interface Overview 1.4 Product Label 15 1.4 Product Label The labels fixed to the bottom of a GWM300 comprise the following information. 1 *:0 3 * 0RGHP 4 && 2 PP 5 6 PP 7 61 8 ,0(, 0DGH LQ &KLQD 9 10 11 Figure 1: Sample GWM300 labels Table 8: GWM300 label information No.
GWM300 Hardware Interface Overview Page 16 of 35 2 Product Concept 18 2 Product Concept 2.1 Key Features at a Glance Feature Implementation General Incorporates Cinterion® Java module The Java module handles all signal and data processing within the GWM300. Internal software runs the application interface and the complete GSM/UMTS protocol stack.
GWM300 Hardware Interface Overview Page 17 of 35 2.
GWM300 Hardware Interface Overview Page 18 of 35 2.1 Key Features at a Glance 18 Feature Implementation Interfaces RS232 RS-232 interface as part of 8-pin Molex Microfit for AT commands and data: • Supports RTS/CTS hardware handshake • Supports software XON/XOFF flow control • Multiplex ability according to GSM 07.
GWM300 Hardware Interface Overview Page 19 of 35 3 Interface Description 26 3 Interface Description 3.1 Overview GWM300 provide the following interfaces for power supply, operating status indication, antenna, SIM card and data transfer: Table 9: GWM300‘ interfaces No.
Page 20 of 35 GWM300 Hardware Interface Overview 3.2 Block Diagram 26 3.2 Block Diagram Figure 3 shows a block diagram of a sample configuration that incorporates a GWM300 and typical accessories.
GWM300 Hardware Interface Overview Page 21 of 35 3.3 Operating Modes 26 3.3 Operating Modes The table below briefly summarizes the various operating modes referred to in the following chapters. Table 10: Overview of operating modes Normal operation GSM IDLE Software is active. Once registered to the GSM network paging with BTS is carried out. The Terminal is ready to send and receive. Watchdog active. GSM TALK GSM DATA Connection between two subscribers is in progress.
GWM300 Hardware Interface Overview Page 22 of 35 3.4 Molex Microfit Connector 26 3.4 Molex Microfit Connector Via the 8-pin Molex Microfit connector, the host application controller controls the GWM300 (including power supply), and transports data. Figure 4: Pin assignment Molex Microfit Table 11: 8-pin Molex Microfit connector Pin no.
GWM300 Hardware Interface Overview Page 23 of 35 3.4 Molex Microfit Connector 26 3.4.1 RS-232 Interface The RS-232 interface is implemented as a serial asynchronous transmitter and receiver conforming to ITU-T V.24 Interchange Circuits DCE.
GWM300 Hardware Interface Overview Page 24 of 35 3.5 Power Up/Power Down Scenarios 26 3.5 Power Up/Power Down Scenarios In general, be sure not to turn on the GWM300 while it is beyond the safety limits of voltage stated in Section 4.1. GWM300 immediately switches off after having started and detected these inappropriate conditions. In extreme cases this can cause permanent damage to the GWM300. 3.5.
Page 25 of 35 GWM300 Hardware Interface Overview 3.6 SIM Interface 26 3.6 SIM Interface The SIM interface is intended for 1.8V and 3V SIM cards in accordance with GSM 11.12 Phase 2. The card holder is a five wire interface according to GSM 11.11. The SIM card holder is protected by a rubber cover that has to be opened before a SIM can be inserted.
GWM300 Hardware Interface Overview Page 26 of 35 3.8 RF Antenna Interface 26 3.8 RF Antenna Interface An external RF antenna is connected via the GWM300’s female FME connector that is also the antenna reference point (ARP). Figure 7: Antenna connector The system impedance is 50. In any case, for good RF performance, the return loss of the customer application’s antenna should be better than 10dB (VSWR < 2). GWM300 withstand a total mismatch at this connector when transmitting with maximum RF power.
Page 27 of 35 GWM300 Hardware Interface Overview 4 Mechanics, Mounting and Packaging 29 4 Mechanics, Mounting and Packaging 4.1 Mechanical Dimensions Figure 8 shows a 3D view of the GWM300 and provides an overview of the mechanical dimensions of the terminal. For further details and an exploded view see Figure 9. Length: Width: Height: 71mm (excluding antenna and connector interfaces) 51.5mm 23.5mm Weight: 60g 23.5mm 51.
GWM300 Hardware Interface Overview Page 28 of 124 4.
GWM300 Hardware Interface Overview Page 29 of 35 4.2 Packaging 29 4.2 Packaging GWM300 terminal units come in bubble bags stashed into VP boxes made out of corrugated fiberboard: • VP box size: 370mm x 350mm x 155mm A VP box contains up to 80 terminal units, stashed into two layers of up to 40 units. Terminal layers are separated by foam layers for protective purposes.
Page 30 of 35 GWM300 Hardware Interface Overview 5 Full Type Approval 33 5 Full Type Approval 5.
GWM300 Hardware Interface Overview Page 31 of 35 5.2 Restrictions 33 5.2 Restrictions Later enhancements and modifications beyond the certified configuration require extra approvals. Each supplementary approval process includes submittal of the technical documentation as well as testing of the changes made. • No further approvals are required for customer applications that comply with the approved GWM300 configuration.
GWM300 Hardware Interface Overview Page 32 of 35 5.5 Compliance with FCC and IC Rules and Regulations 33 5.5 Compliance with FCC and IC Rules and Regulations As an integrated product, GWM300 is fully compliant with the grant of the FCC Equipment Authorization and the Industry Canada Certificates issued for the built-in Java modules, and therefore, bears the labels “Contains FCC ID: QIPEHS6”.
GWM300 Hardware Interface Overview Page 33 of 35 5.5 Compliance with FCC and IC Rules and Regulations 33 Notes (IC): (EN) This Class B digital apparatus complies with Canadian ICES-003 and RSS-210. Operation is subject to the following two conditions: (1) this devive may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Page 34 of 35 GWM300 Hardware Interface Overview 6 List of Parts and Accessories 34 6 List of Parts and Accessories Table 12: List of parts and accessories Description Supplier Ordering information GWM300 Gemalto Ordering number L30960-N4300-A100 8-pin receptacle Molex Microfit (3.
About Gemalto Gemalto (Euronext NL0000400653 GTO) is the world leader in digital security with 2014 annual revenues of €2.5 billion and blue-chip customers in over 180 countries. Our 14,000 employees operate out of 99 offices, 34 personalization and data centers, and 24 research and software development centers located in 46 countries. Gemalto develops secure embedded software and secure products which we design and personalize.