User's Manual
Table Of Contents
- Contents
- Tables
- Figures
- 1 Introduction
- 2 Interface Characteristics
- 2.1 Application Interface
- 2.1.1 Pad Assignment
- 2.1.2 Signal Properties
- 2.1.3 USB Interface
- 2.1.4 Serial Interface ASC0
- 2.1.5 Serial Interface ASC1
- 2.1.6 UICC/SIM/USIM Interface
- 2.1.7 Digital Audio Interface
- 2.1.8 Pulse Code Modulation Interface (PCM)
- 2.1.9 Inter IC Sound Interface (I2S)
- 2.1.10 GPIO Interface
- 2.1.11 I2C Interface
- 2.1.12 SPI Interface
- 2.1.13 Pulse Counter
- 2.1.14 HSIC Interface (ELS51-VA Only)
- 2.1.15 SDIO Interface (ELS51-VA Only)
- 2.1.16 Control Signals
- 2.2 RF Antenna Interface
- 2.3 Sample Application
- 2.1 Application Interface
- 3 Operating Characteristics
- 3.1 Operating Modes
- 3.2 Power Up/Power Down Scenarios
- 3.3 Power Saving
- 3.4 Power Supply
- 3.5 Operating Temperatures
- 3.6 Electrostatic Discharge
- 3.7 Blocking against RF on Interface Lines
- 3.8 Reliability Characteristics
- 4 Mechanical Dimensions, Mounting and Packaging
- 5 Regulatory and Type Approval Information
- 6 Document Information
- 7 Appendix
Cinterion
®
ELS31-VA/ELS51-VA Hardware Interface Description
4.2 Mounting ELS31-VA/ELS51-VA onto the Application Platform
92
ELS31-VA_ELS51-VA_HID_v01.000 2017-01-04
Confidential / Preliminary
Page 84 of 106
4.2.4 Durability and Mechanical Handling
4.2.4.1 Storage Conditions
ELS31-VA/ELS51-VA modules, as delivered in tape and reel carriers, must be stored in sealed,
moisture barrier anti-static bags. The conditions stated below are only valid for modules in their
original packed state in weather protected, non-temperature-controlled storage locations. Nor-
mal storage time under these conditions is 12 months maximum.
Table 24: Storage conditions
Type Condition Unit Reference
Air temperature: Low
High
-25
+40
°C IPC/JEDEC J-STD-033A
Humidity relative: Low
High
10
90 at 40°C
%
IPC/JEDEC J-STD-033A
Air pressure: Low
High
70
106
kPa IEC TR 60271-3-1: 1K4
IEC TR 60271-3-1: 1K4
Movement of surrounding air 1.0 m/s IEC TR 60271-3-1: 1K4
Water: rain, dripping, icing and
frosting
Not allowed --- ---
Radiation: Solar
Heat
1120
600
W/m
2
ETS 300 019-2-1: T1.2, IEC 60068-2-2 Bb
ETS 300 019-2-1: T1.2, IEC 60068-2-2 Bb
Chemically active substances Not
recommended
IEC TR 60271-3-1: 1C1L
Mechanically active substances Not
recommended
IEC TR 60271-3-1: 1S1
Vibration sinusoidal:
Displacement
Acceleration
Frequency range
1.5
5
2-9 9-200
mm
m/s
2
Hz
IEC TR 60271-3-1: 1M2
Shocks:
Shock spectrum
Duration
Acceleration
Semi-sinusoidal
1
50
ms
m/s
2
IEC 60068-2-27 Ea