User's Manual
Table Of Contents
- Contents
- Tables
- Figures
- 1 Introduction
- 2 Interface Characteristics
- 2.1 Application Interface
- 2.1.1 Pad Assignment
- 2.1.2 Signal Properties
- 2.1.3 USB Interface
- 2.1.4 Serial Interface ASC0
- 2.1.5 Serial Interface ASC1
- 2.1.6 UICC/SIM/USIM Interface
- 2.1.7 Digital Audio Interface
- 2.1.8 Pulse Code Modulation Interface (PCM)
- 2.1.9 Inter IC Sound Interface (I2S)
- 2.1.10 GPIO Interface
- 2.1.11 I2C Interface
- 2.1.12 SPI Interface
- 2.1.13 Pulse Counter
- 2.1.14 HSIC Interface (ELS51-VA Only)
- 2.1.15 SDIO Interface (ELS51-VA Only)
- 2.1.16 Control Signals
- 2.2 RF Antenna Interface
- 2.3 Sample Application
- 2.1 Application Interface
- 3 Operating Characteristics
- 3.1 Operating Modes
- 3.2 Power Up/Power Down Scenarios
- 3.3 Power Saving
- 3.4 Power Supply
- 3.5 Operating Temperatures
- 3.6 Electrostatic Discharge
- 3.7 Blocking against RF on Interface Lines
- 3.8 Reliability Characteristics
- 4 Mechanical Dimensions, Mounting and Packaging
- 5 Regulatory and Type Approval Information
- 6 Document Information
- 7 Appendix
Cinterion
®
ELS31-VA/ELS51-VA Hardware Interface Description
3.8 Reliability Characteristics
76
ELS31-VA_ELS51-VA_HID_v01.000 2017-01-04
Confidential / Preliminary
Page 76 of 106
3.8 Reliability Characteristics
The test conditions stated below are an extract of the complete test specifications.
Table 22: Summary of reliability test conditions
Type of test Conditions Standard
Vibration Frequency range: 10-20Hz; acceleration: 5g
Frequency range: 20-500Hz; acceleration: 20g
Duration: 2h per axis; 3 axes
DIN IEC 60068-2-6
1
1. For reliability tests in the frequency range 20-500Hz the Standard’s acceleration reference value was
increased to 20g.
Shock half-sinus Acceleration: 500g
Shock duration: 1ms
1 shock per axis
6 positions (± x, y and z)
DIN IEC 60068-2-27
Dry heat Temperature: +70 ±2°C
Test duration: 16h
Humidity in the test chamber: < 50%
EN 60068-2-2 Bb
ETS 300 019-2-7
Temperature
change (shock)
Low temperature: -40°C ±2°C
High temperature: +85°C ±2°C
Changeover time: < 30s (dual chamber system)
Test duration: 1h
Number of repetitions: 100
DIN IEC 60068-2-14 Na
ETS 300 019-2-7
Damp heat cyclic High temperature: +55°C ±2°C
Low temperature: +25°C ±2°C
Humidity: 93% ±3%
Number of repetitions: 6
Test duration: 12h + 12h
DIN IEC 60068-2-30 Db
ETS 300 019-2-5
Cold (constant
exposure)
Temperature: -40 ±2°C
Test duration: 16h
DIN IEC 60068-2-1