2.1.16 Control Signals
2.1.16.1 Status LED
The LED line can also be configured as GPO5 line, and can be used to drive a status LED that
indicates different operating modes of the module (for GPOs see Section 2.1.10). LED and
GPO functionality are mutually exclusive.
To take advantage of this function connect an LED to the LED/GPO5 line as shown in Figure
18.
Figure 18: Status signaling with LED driver
VCC
GPO5/
LED
LED
GNDGND
R1
R2
R3