ALS3-US R4 Hardware Interface Overview
2.1 Key Features at a Glance
18
ALS3-USR4_HIO_v03.915 2017-03-27
Confidential / Preliminary
Page 17 of 44
Antenna 50. GSM/UMTS/LTE main antenna, UMTS/LTE Diversity/MIMO
antenna, (active/passive) GNSS antenna
USB USB 2.0 High Speed (480Mbit/s) device interface
Serial interface ASC0:
8-wire modem interface with status and control lines, unbalanced,
asynchronous
Adjustable baud rates: 115,200bps to 921,600bps
Supports RTS0/CTS0 hardware flow control
UICC interface 2 UICC interfaces (switchable)
Supported chip cards: UICC/SIM/USIM 3V, 1.8V
Audio 1 digital interface (PCM or I
2
S)
1 analog interface with microphone feeding
Status Signal line to indicate network connectivity state
RING0 Signal line to indicate incoming calls and other types of
URCs
Power on/off, Reset
Power on/off Switch-on by hardware signal IGT
Switch-off by AT command (AT^SMSO) or IGT
Automatic switch-off in case of critical temperature or voltage conditions
Reset Orderly shutdown and reset by AT command
Emergency-off Emergency-off by hardware signal EMERG_OFF if IGT is not active
Special Features
Antenna SAIC (Single Antenna Interference Cancellation) / DARP (Downlink
Advanced Receiver Performance)
Rx Diversity (receiver type 3i - 64-QAM) / MIMO
GPIO 10 I/O pins of the application interface programmable as GPIO.
GPIOs can be configured as low current indicator (LCI).
GPIOs can be configured for antenna diagnosis.
GPIO1 can be configured as dead reckoning synchronization signal.
GPIO2 can be configured as 700MHz antenna switch control signal.
GPIOs can be configured as remote host wakeup lines.
Programming is done via AT commands.
ADC inputs Analog-to-Digital Converter with three unbalanced analog inputs for
(external) antenna diagnosis.
Evaluation kit
Evaluation module ALS3-US R4 module soldered onto a dedicated PCB that can be con-
nected to an adapter in order to be mounted onto the DSB75.
DSB75 DSB75 Development Support Board designed to test and type approve
Gemalto M2M modules and provide a sample configuration for applica-
tion engineering. A special adapter is required to connect the ALS3-US
R4 evaluation module to the DSB75.