User's Manual
AC65/AC75 Hardware Interface Description
Confidential / Preliminary
s
AC65/AC75_hd_v00.372 Page 45 of 118 2006-08-03
Table 8: Specifications of battery packs suitable for use with AC65/AC75
Battery type Rechargeable Lithium Ion or Lithium Polymer battery
Nominal voltage 3.6V / 3.7V
Capacity Recommended: 1000mAh to 1200mAh
Minimum: 500mAh
NTC 10k ± 5% @ 25°C
approx. 5k @ 45°C
approx. 26.2k @ 0°C
B value range: B (25/85)=3423K to B =3435K ± 3%
Overcharge detection voltage 4.325 ± 0.025V
Overdischarge detection voltage 2.5V
Overdischarge release voltage 2.6V
Overcurrent detection 3 ± 0.5A
Overcurrent detection delay time 4 ~ 16ms
Short detection delay time 50µs
Internal resistance <130m
Note: A maximum internal resistance of 150m should not
be exceeded even after 500 cycles and under extreme
conditions.
3.5.4 Charger Requirements
For using the implemented charging algorithm and the reference charging circuit
recommended in [4] and in Figure 46, the charger has to meet the following requirements:
Output voltage: 5.2Volts ±0.2V (stabilized voltage)
Output current: 500mA
Chargers with a higher output current are acceptable, but please
consider that only 500mA will be applied when a 0.3Ohms shunt
resistor is connected between VSENSE and ISENSE. See [4] for
further details.