USB•100 USER MANUAL www.gefen.
Gefen Inc.
rrants the manufactures m defects in workmanship. pment fails ch defects c. is notified year from ASKING FOR ASSISTANCE Technical Support: Telephone (818) 884-6294 (800) 545-6900 Fax (818) 884-3108 Technical Support Hours: 8:00am to 5:00pm Monday thru Friday Write To: Gefen, Inc. C/O Customer Service 6265 Variel Avenue Woodland Hills, CA 91367-9897 Notice Gefen Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written notice.
TABLE OF CONTENTS 1 Introduction 2 Operation Notes 3 USB Series Installation 4 USB•100 Panel Layout 5 USB•100 Function Description 6 Wiring Diagram 7 Link Cable Diagram 8 Check List 9 Troubleshooting Hints 10 Warranty
INTRODUCTION Thank you for purchasing the ex•tend•it USB•100 Series. The new USB•100 incorporates ExtremeUSB™ techology, which allows users the benefits of USB technology beyond the desktop. Extending your USB peripherals (i.e. computer keyboard, mouse or trackball) up to 330 feet away from the location of your Macintosh or PC computer are done easily with the USB•100. The USB•100 system consists of two units.
OPERATION NOTES READ THESE NOTES BEFORE INSTALLING OR OPERATING THE USB•100 SYSTEM. * The USB•100 send and receive were designed to operate on USB enabled computers. DO NOT attempt to use this equipment with any other type of computer. * Use the computer's USB port when using a local keyboard that is not extended with the USB•100 sender unit. * In order to operate properly, the USB•100 receiver unit must be connected, powered, and the CAT-5 cable must be installed between the send and receive units.
USB•100 SERIES INSTALLATION 1. Place the USB•100R unit close to the USB devices at the remote end. 2. Connect the USB devices to the USB•100R unit. 3. Connect the power adapter to a suitable DC source wall outlet. 4. Connect the power adapter to the USB•100R unit using the supplied cable. 5. Place the USB•100S unit close to the host computer. 6. Connect the USB•100S unit to the USB•100R unit using the desired length of CAT5 cable 7.
USB•100 PANELS LAYOUT USB•100S USB In 1 2 Power Link 3 4 5 6 USB•100R Link 7 8 USB•100R USB OUT 11 12 4 Power 9 10
USB•100 FUNCTION DESCRIPTION 1 USB LED - Indicates if a USB connection is made properly 2 USB In - USB cable (A-B) cable from computer to sender 3 Link LED - Indicates if a link between the USB•100S send and the USB•100R Receive units 4 Link - CAT-5 Modular Jack which connects to the USB•100S send and the USB•100R Receive units 5 Power LED - Indicates the unit is plugged in and powered up. 6 DC IN - Power plug for 15VDC Wallmount power supply.
USB•100R 6 Up to 330 feet using CAT5 cable USB•100S WIRING DIAGRAM
7 1 8 8 7 6 5 4 3 2 1 RJ-45 Jack Orange White/Orange Green White/Brown Brown White/Green Blue White/Blue 8 7 6 5 4 3 2 1 1 8 LINK CABLE - WIRING DIAGRAM
CHECK LIST 1. On the USB•100S send unit, check that the power indicator is GREEN. 2. On the USB•100S send unit, check that the link indicator is GREEN. 3. On the USB•100R receiver unit, check that the power indicator is GREEN. 4. Once all LEDs are illuminated as suggested, the USB•100 is ready to accept a USB peripheral device at the USB port on the USB•100R receiver unit. Follow the installation instructions as if one were installing the device directly into a computer's USB port. 5.
TROUBLESHOOTING HINTS Power Indicator is not lit. -- Make certain the power supply unit is properly connected to the USB•100R unit and to a proper local power supply outlet. Link Indicators are Green. -- Make certain that the host computer is operating and responding to commands. If required, reset the computer. Problem Not Resolved -- Disconnect power (DC Adaptor) plug from wall outlet that feeds power to the USB•100R unit. -- Disconnect the USB•100S USB connection from the computer.
WARRANTY Gefen Inc. warrants the equipment it manufactures to be free from defects in material and workmanship. If equipment fails because of such defects and Gefen Inc. is notified within two (2) year from the date of shipment, Gefen Inc. will, at its option repair or replace the equipment, provided that the equipment has not been subjected to mechanical, electrical, or other abuse or modifications.