User manual

38
RS-232 / IP / UDP CONTROL
IP Conguration
The32x32 Modular MatrixsupportsIP-basedcontrolusingTelnet,UDP,orthebuilt-in
Web-basedGUI.TosetupIPcontrol,thenetworksettingsforthe32x32 Modular Matrix
mustbeconguredviaRS-232.Thedefaultnetworksettingsforthematrixareasfollows:
IPAddress: 192.168.1.72
Subnet: 255.255.255.0
Gateway: 192.168.1.254
HTTPPort: 80
TelnetPort: 23
1. ConnectanRS-232cablefromthePCtothe32x32 Modular Matrix.Alsomakesure
thatanEthernetcableisconnectedbetweenthematrixandthenetwork.
2. Launchaterminalemulationprogram(e.g.HyperTerminal)andusetheRS-232
settingslistedonpage37.
3. SettheIPaddressforthematrixusingthe#sipaddcommand(seepage55
fordetails).
4. Setthesubnetmaskusingthe#snetmaskcommand(seepage55fordetails).
5. Setthegateway(router)IPaddressusingthe#sgatewaycommand
(seepage53fordetails).
6. SettheTelnetlisteningportusingthe#set_tcp_term_portcommand
(seepage51fordetails).
7. SettheHTTPlisteningportusingthe#set_http_portcommand
(seepage50fordetails).
8. Power-cyclethematrixtorebootandcompleteallIPsettingchanges.
9. TypetheIPaddressthatwasspeciedinstep3,inawebbrowsertoaccess
theWebGUIorusethesameIPaddresstoTelnettothematrix.
UDP Conguration
1. SettheUDPremoteIPaddressforthematrixusingthe#set_udp_ripcommand
(seepage52fordetails).
2. SettheUDPlisteningportforthematrixusingthe#set_udp_portcommand(see
page52fordetails).
3. SettheUDPremoteportforthematrixusingthe#set_udp_rportcommand(see
page53fordetails).
NOTE:Dependinguponthenetwork,allrelatedIP,Telnet,and
UDPsettingswillneedtobeassigned.Consultyournetwork
administratortoobtainthepropersettings.