CONNECTING THE 32X32 MODULAR MATRIX
DisplayPort package options
EachDisplayPortpackageisbasedontheDVIpackageoptions,exceptforthefactthatall
inputswillbeDisplayPortinsteadofDVI.RefertotheconnectioninstructionsfortheDVI
versionofeachpackageifneeded.
• GEF-MOD-32432-DPDVI (based on the GEF-MOD-32432-DVI)
1. Connecttheupto32DisplayPortsourcestotheDisplayPortinputsonthematrix.
2. Connectionupto32displaystotheDVIoutputsonthematrixusingDVIcables.
3. Powerthematrix.
• GEF-MOD-32432-DPELR (based on the GEF-MOD-32432-DVIELR)
1. Connecttheupto32DisplayPortsourcestoeachDisplayPortinputonthe
matrix.
2. ConnectaCAT-5ecable(orbetter),upto330feet(100meters)
fromeachELR-POLjackontheoutputcardtoeachoftheincludedELR-POL
Receiverunits.
3. Powerthematrix.
Oncethematrixispowered,theLinkindicatorswillglowbrightgreentoindicate
asolidlinkbetweentheMatrixcardandtheReceiverunit.
ThePOLindicatorswillglowbrightambertoindicatethattheReceiverunitis
beingpowered.
• GEF-MOD-32432-DP1FO (based on the GEF-MOD-32432-DVI1FO)
1. FollowtheVirtualEDIDProgrammingProcedurestartingonpage16.
2. Connectupto32DisplayPortsourcestotheDisplayPortinputsonthematrix.
3. ConnectasinglestrandofSC-terminated50μOM3emultimodeberopticcable
fromeachSCconnectorontheSendermoduletoeachReceivermodule.
50μOM3e,OM3,and62.5μOM1multimodeberopticcablecanbeused.
However,themaximumextensiondistanceisdependentuponthetypeofber
opticcableused:
• 6600feet(2kilometers)using50μOM3emultimodeberopticcable.
• 2000feet(600meters)using50μOM3multimodeberopticcable.
• 660feet(200meters)using62.5μOM1multimodeberopticcable.
3. Connectthepowersupplytothe1FOReceiverunitthenconnectthepower
supplytoanavailableelectricaloutlet.
4. Powerthematrix.