User manual
24
APPENDIX B
#PRBAEDID_param1_param2\r
Parameter Name Value
1 EDID bank offset [1:7]
2
Send BIN fi le 0
Send TXT fi le 1
Print EDID Setting
This function sends the EDID setting table to the serial port.
#PRSEEDID\r
Load EDID To Locals EDID
These functions will load an EDID fi le through the serial port and store it in any
Input’s Local EDID.
#LOEDIDTOLO_param1_param2_param3[_param4][_param5][_param6]
[_param7][_param8][_param9][_param10]\r
Parameter Name Value
1
Semi echo mode 0
Full echo mode 1
2
EDID.bin fi le (256 bytes) 1
EDID.bin fi le (256 bytes) 2
3 (4-10 optionally) INPUT [1:8]
Load EDID To EDID Bank
This function loads and EDID through the serial port and store it in the EDID
bank.
#LOEDIDTOBA_param1_param2\r
Parameter Name Value
1
Semi echo mode 0
Full echo mode 1
2
EDID.bin fi le (256 bytes) 1
EDID.bin fi le (256 bytes) 2
3 EDID bank offset [1:7]