User manual
page | 6
Connection Instructions
1. Connect the included DVI cable from the imaging source (e.g. camera) to the DVI In
port on the Sender unit.
2. Connect a DVI cable from the DVI Out port, on the Receiver unit, to a video scaler or
high-resolution imaging display.
3. Connect a single CAT-5e or better cable from the Link jack on the Sender unit to the
Link jack on the Receiver unit.
4. Connect a ground wire from the grounding terminals, on both the Sender and
Receiver unit, to an approved Earth ground. The ground wire should not be less
than 16 AWG.
5. Use the included locking power supplies to connect the Sender and Receiver unit to
available electrical outlets. Do not overtighten the locking power connectors.
Sample Wiring Diagram
Installation
Getting Started
EXT-DVI-1CAT6-GI
Sender
Receiver
(such as a Medical Imaging Camera)
DVI Display
DVI CABLE
CAT-5e or CAT-6A CABLE
Galvanically Isolated
DVI Source
Important!
The grounding terminal must be permanently connected to an approved Earth
ground by wiring not less than 16 AWG.