*Preferred 3GSDI Audio Embedder DVI over 1 CAT6 w/ Galvanic Isolator EXT-DVI-1CAT6-GI User Manual Release A2
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this product near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install or place this product near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9.
Warranty Information Gefen warrants the equipment it manufactures to be free from defects in material and workmanship. If equipment fails because of such defects and Gefen is notified within two (2) years from the date of shipment, Gefen will, at its option, repair or replace the equipment, provided that the equipment has not been subjected to mechanical, electrical, or other abuse or modifications.
Contacting Gefen Technical Support Technical Support (818) 772-9100 (800) 545-6900 8:00 AM to 5:00 PM Monday - Friday, Pacific Time Fax (818) 772-9120 Email support@gefen.com Web http://www.gefen.com Mailing Address Gefen, LLC c/o Customer Service 20600 Nordhoff St. Chatsworth, CA 91311 Product Registration Register your product here: http://www.gefen.com/kvm/Registry/Registration.
Operating Notes • Always connect a bonding wire between an approved safety ground and the grounding screw on the chassis. • Electromagnetic Interference This product is subject to the following two conditions: ►► This device may not cause harmful interference ►► This device must accept any interference received including interference that may cause undesired operation. • Use only the AC/DC adapter supplied by the manufacturer.
Features and Packing List Features • Compliant with Medical Standards EN60601-1 and EN60601-1-2, 3rd Edition • Extends DVI up to 132 feet (40 meters) over CAT-6a • Extends DVI up to 100 feet (30 meters) over CAT-5e • Provides up to 5kV galvanic isolation between the source and the downstream equipment • Supports resolutions up to 1080p Full HD and 1920 x 1200 (WUXGA) • HDCP pass-through • Switchable Deep Color support • HPD pass-through • EDID management switch for rapid integration of sour
Table of Contents 1 Getting Started Introduction............................................................................................................ 2 Sender unit..................................................................................................... 2 Receiver unit.................................................................................................. 4 Installation..............................................................................................................
DVI over 1 CAT6 w/ Galvanic Isolator 1 Getting Started Introduction............................................................................................................ 2 Sender unit..................................................................................................... 2 Receiver unit.................................................................................................. 4 Installation............................................................................................
Introduction Page Title Getting Started Sender unit 1 EXT-DVI-1CAT6-GIS Gefen EXT-DVI-1CAT6-GIS Gefen EXT-DVI-1CAT6-GIS Gefen Link Link Link DVI DVI DVI over 1 CAT6 w/ Galvanic Isolator S over 1 CAT6 w/ Galvanic Isolator S over 1 CAT6 w/ Galvanic Isolator S 2 3 4 5V DC Power DVI In 5V DC Power DVI In 5V DC Power DVI In page | 2 5
Getting Started Introduction Page Title ID Name Description 1 Link Connect a CAT-5e cable (or better) from this port to the Link port on the Receiver unit. 2 5V DC Connect the included 5V DC power supply to this power receptacle. 3 Power This LED will glow bright blue once the included 5V DC power supply has been properly connected between the locking power receptacle and an available electrical outlet. 4 DVI In Connect the included DVI cable between the imaging source (e.g.
Introduction Page Title Getting Started Receiver unit 1 EXT-DVI-1CAT6-GIR Gefen EXT-DVI-1CAT6-GIR Gefen EXT-DVI-1CAT6-GIR Gefen Link Link Link DVI DVI DVI over 1 CAT6 w/ Galvanic Isolator R over 1 CAT6 w/ Galvanic Isolator R over 1 CAT6 w/ Galvanic Isolator R 4 5 7 DVI Out 0 Power 7 5V DC 2 7 EQ 6 page | 4 4 0 1 6 DVI Out 5 Power 6 5V DC 2 1 EQ 3 DVI Out 4 Power 3 5V DC 4 0 2 3 1 6 5 3 5 2 EQ
Getting Started Introduction Page Title ID Name Description 1 Link Connect a CAT-5e cable (or better) from this port to the Link port on the Sender unit. 2 5V DC Connect the included 5V DC power supply to this power receptacle. 3 Power This LED will glow bright blue once the included 5V DC power supply has been properly connected between the locking power receptacle and an available electrical outlet. 4 DVI Out Connect a DVI cable between the imaging system (display) and the DVI Out port.
Getting Started Installation Connection Instructions 1. Connect the included DVI cable from the imaging source (e.g. camera) to the DVI In port on the Sender unit. 2. Connect a DVI cable from the DVI Out port, on the Receiver unit, to a video scaler or high-resolution imaging display. 3. Connect a single CAT-5e or better cable from the Link jack on the Sender unit to the Link jack on the Receiver unit. 4.
DVI over 1 CAT6 w/ Galvanic Isolator 2 Basic Operation DIP Switch Configuration..................................................................................... 10 Default Settings............................................................................................ 10 EDID Management....................................................................................... 11 Color Management.......................................................................................
5V DC Power DVI In On the bottom panel of the Sender unit is a bank of 4 DIP switches. Remove the piece of colored tape to reveal the DIP switch bank. These DIP switches provide control over EDID management and color depth. DIP switches 3 and 4 are not used. CTS 219 117 ON 1 3 4 CTS 219 117 ON 2 1 2 3 4 Default Settings The following table lists the default (factory) settings of each DIP switch. See the following page for details on each DIP switch function.
EDID Management The DVI over 1 CAT6 w/ Galvanic Isolator can be switched between two EDID modes: Internal or Pass-through. After changing DIP switch 1, the Sender unit must be power-cycled for changes to take effect. ON (default) Pass-through mode. DDC and HPD are passed through. Both the connection status and the full video capabilities of the monitor are passed to the source device. ON 1 3 ON 4 CTS 117 Internal EDID mode. In this mode, a generic EDID will be sent to the source device.
The Receiver unit of the DVI over 1 CAT6 w/ Galvanic Isolator has a trim pot that is used to equalize the output signal, compensating for extension distance and cable skew. If there is no output video or if output video contains video artifacts and/or video noise such as snow, use the steps below to adjust the trim pot. over 1 CAT6 DVI w/ Galvanic Isolator R 1. Use a small flat-headed tool to turn the EQ pot. 2. The trim pot has eight different positions (0 through 7).
DVI over 1 CAT6 w/ Galvanic Isolator 3 Appendix Surface Mounting Instructions.............................................................................. 16 Specifications.......................................................................................................
Appendix Surface Mounting Instructions The Sender and Receiver units can be mounted on any flat surface, as shown below (screws not included). There should be an inch or two of clearance between the edges of the unit and any walls or vertical surfaces to allow for enough clearance for connection and disconnection of the DVI cables. For installation on a drywall surface, use a #6 drywall screw. When installing, it is recommended to use the center hole on a stud.
Appendix Specifications Connectors & Indicators Video Input (Sender) • 1 x DVI 29-pin, female (digital only) Video Output (Receiver) • 1 x DVI 29-pin, female (digital only) Link (Sender / Receiver) • 1 x RJ-45 Power (Sender / Receiver) • 1 x Locking-type Power Indicator (Sender / Receiver) • 1 x LED, blue EDID Selector (Sender) • 1 x DIP switch Deep Color Selector (Sender) • 1 x DIP switch EQ Adjustment (Receiver) • 1 x 8-position rotary switch Maximum Pixel Clock • 165 MHz Power
*Preferred Stretch it. Switch it. Split it. Gefen’s got it. ® 20600 Nordhoff St., Chatsworth CA 91311 1-800-545-6900 818-772-9100 fax: 818-772-9120 www.gefen.com support@gefen.