Operation Manual English Door control MiniMax 3 S EN conform: EN12453 (Safety in use of power operated doors) Page 1 of 8 Revision 03
Operation Manual English The door control DC MiniMax 3 S is designed for hold to run control of power operated doors. The basic version is designed for hold to run operation only, but it can be extended individually by an optional module. Safety Directions • In case of using DC MiniMax 3 S with a permanent mains connection, an all-pole main switch with an appropriate back-up fuse must be provided. • With three phase motor connection an external fuse in the main supply should be max. 10A delayed.
Operation Manual English Main board DC MiniMax 3S Terminal: selection of Klemme Selector supply Spannungswahl supply voltagevoltage (X4) Connector Klemmleiste Connector Motor & +safety chain Motor Sicherheitskette Terminal: Motor + Safety Switch (X2) Netzanschluss supply voltage(X1) Mains supply PE PE 400V/230V Connector External pushStecksockel für button station ext.
Operation Manual English 6 Main Board DC MiniMax 3S 4 5 S6 3 2 S9 S10 S8 S11 S12 S14 S16 5 J1 S13 S15 OPEN AUF X4 1 J4 2 3 X6 S01 CLOSE ZU S02 X9 1 2 K3 J3 J2 2 X10 X8 J5 24V DC 50 mA 3 4 + 6 PE X7 - 7 8 L3 L2 L1 X1 9 10 11 12 13 14 15 W V U Zuleitung 230V / 50Hz Mains Zuleitung 400V / 50Hz supply S5 1 X5 4 M Motor 230 V / 50Hz Motor 400 V / 50Hz S2 1 S4 X3 S3 X2 F2 5 S7 Selector mains supply Wahl der Netzspannung 230V 400V 1 2 2 3 X4 Page
Operation Manual English Labels F2 K1 K2 K3 M1 S01 S02 S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 Thermal protection Contactor Close Contactor Open Traffic Light Motor connection Installation switch Open Installation switch Close Aux. limit switch Open Limit switch Open (NC) Safety limit switch Open (NC) Safety limit switch (NC) Limit switch Close (NC) Aux.
Operation Manual English Wiring Diagrams 15 STOP 14 13 OPEN 12 9 Brown / +12V 8 Green / Signal 7 White / GND 6 - 5 + 2 1 8 Not connected 8k2 7 CLOSE 10 3 9 1 2 11 4 Electrical Safety edge P DIP Switch 1 OFF Pro-Sec-O* OSE* 24 V DC Pneumatic Safety edge 9 IMPULSE* 8 Not connected 8k2 7 Photobeam* DIP Switch 7 ON X3 2 1 Relais output* for traffic light or courtesy light X9 * only possible, if comfort module is used Page 6 of 8 Revision 03
Operation Manual English Jumper settings J4 Stecksockel für Ext. 3- fach Taster Connector external push button station - wird der Steckplatz nicht belegt, muss der if not used, J4 has to be bricked X6 Jumper 4, gesteckt sein. ZU AUF STOP CLOSE OPEN STOP J3 Stecksockel für Spiralkabel Connector spiral cord - wird der Steckplatz nicht belegt, muss der if not used, J3 has to be bricked Jumper 3, gesteckt sein.
English Operation Manual Comfort module Page 8 of 8 Revision 03