Operation Manual

Operation manual
For use with DC MiniMax 3 S or R
English
1 The testing of the pneumatic safety edge takes place in the lower door position. Please
ensure that the safety edge is activated in the lower door position. The Aux. Limit switch
Close has to be used.
2 2 minute night light period is activated by every movement of the door. If the prewarning is
activated, the courtesy light starts 5 seconds before the door movement.
3 Red traffic light with prewarning
- prewarning 3 sec. flashing before automatic closing
- prewarning 3 sec. flashing before any movement of the door,
permanent on during the movement, 5 sec. post illumination period
Red traffic light without prewarning
- prewarning 3sec. flashing before automatic closing
- permanent on during the movement, 5 sec. post illumination period
4 Dip switch 4 "ON" = GO function on ( OPEN PUSHBUTTON ). The OPEN pushbutton
opens a door, reversing a closing door. DIP switch 4 OFF, the OPEN pushbutton only opens
a door.
LED Signals
LED flashing - operating state
LED 1 x flashing - Safety edge actuated
LED 2 x flashing - Photobeam activated / error, Safety edge
error or DIP 1 setting wrong
LED 3 x flashing - Primary safety device open or faulty
LED 4 x flashing - Runtime error
LED fast flashing - Automatic closing time has been started
Page 3 of 3 Revision 01