Operation Manual
English
Operation manual
For use with DC MiniMax S or R
Installation
Ü Plug in the board into the connector X7
Ü Plug in Jumper J2 on connector X9
Functionality
Opto- electronical safety edge e.g. Pro-Sec-O
Electrical Safety edge
Pneumatic safety edge with test
Automatic Closing feature
Courtesy or traffic light
Run time monitoring
Dip Switches
LED
Dippschalter
1 - 7
Dip switch ON OFF
1 OPTO SE 8,2 kOhm SE
2 Automatic closing active Automatic closing deactivated
3 Automatic closing time 120 seconds Automatic closing time 30 seconds
4
Open Push Button Go function on
4
Open Push Button Go function off
5
Courtesy light
2
Traffic light (red)
3
6 Prewarning active Prewarning deactivated
7
Pneumatic SE with testing
1
No testing
Page 2 of 3 Revision 01
Dip-Switch 1 -7