Operation Manual
Warning
Assembly, connection and maintenance of the device may only be
executed by personnel trained accordingly. At this the underlying
national and local regulations have to be observed.
The door control DC MiniMAX 3 R is designed for deadman
control of power operated doors.
The basic version is designed for deadman operation only, but it
can be extended individually by optional modules.
Deadman control is only permissible, if the door is in sight of every
control device.
Overview
Terminal external remote control
or pull switch
Terminal external
3-fold push button station
Terminal safety edge
Pro-Sec-O
Terminal: selection of
supply voltage
400V/230V
Terminal supply voltage
Terminal spiral cord
CLOSE
for installation of
limit switches only
OPEN
for installation of
limit switches only
Jumper J2
automatic run CLOSE
(only if safety edge is installed)
Jumper J1
automatic run OPEN
Terminal limit switch and
control devices
Terminal motor