User guide

D
GB
F
E
I
Ru
7
96178-11.2014-DGbFEIRu
GEA Bock GmbH
72636 Frickenhausen, Germany
2| Product description
2.2 Name plate (example)
1 Typedesignation 6 Voltage,circuit,frequency
2 Machine number 7 Nominal rotation speed
3 maximum operating current 8 Displacement
4 Startingcurrent(rotorblocked) 9 Voltage,circuit,frequency
5 ND LP:
max. admissible operating pressur
e 10 Nominal rotation speed
(g)Low pressure side 11 Displacement
HD(HP):
max. admissible operating
12 Oiltypelledatthefactory
pressur
e(g)High pressure side 13 Terminal box protection type
Observe the limits of application Electrical accessories can change
diagrams! the IP protection class!
50 Hz
}
60 Hz
}
/
HG 43 e
380-
4 SX
2.3 Typekey (example)
¹
)
HG-HermeticGas-cooled(suctiongas-cooled)
²
)
X
-Esteroilcharge(HFCrefrigerant,e.g.R134a,R404A/R507,R407C)
3)
S - More powerful motor, e.g. for air-conditioning applications
1
2
3
4
5
13
12
7
11
6
10
8
9
19/28
SE 55
27,3
32,8
HGX34e/315-4
21,1/12,2A
111A 64A
IP66
Fig. 3
AS38125A001
R407C
Refrigerant
Motor variant
3)
Number of poles
Swept volume
e-series
Numbers of cylinders
Size
Oil charge ²
)