Manual
D
GB
F
E
7
09917-02.2015-DGbFEI
2| Product description
/
HG 21 P
75-
4
CO
2
X
2.2 Name plate (example)
2.3 Typekey (example)
¹
)
HG - Hermetic Gas-Cooled (suction gas-cooled)
²
)
X - Ester oil charge
³
)
Additional declaration for Pluscom compressors
CO
2
Version
Number of poles
Swept volume
³
)
Numbers of cylinders
Size
Oil charge ²
)
Series ¹
)
Fig. 3
1
2
3
4
5
7
6
10
8
9
13
12
11
C85E
40/55
AS33567A001
1 Typedesignation 6 Voltage,circuit,frequency
2 Machine number 7 Nominal rotation speed
3 maximum operating current 8 Displacement
4 Startingcurrent(rotorblocked) 9 Voltage,circuit,frequency
5 ND (LP): max. permissible operating 10 Nominal rotation speed
pressure
(g) Low pressure side 11 Displacement
HD (HP):
max. permissible operating
12 Oiltypelledatthefactory
pressur
e (g) High pressure side 13 Terminal box protection type
Observe the limits of application Electrical accessories can change
diagrams! the IP protection class!
50 Hz
}
60 Hz
}
GEA Bock GmbH
72636 Frickenhausen, Germany