8| Technical data
Type
No. of cylinders
Displacement
50/60Hz
(14 50 / 1740
rpm)
Electrical data
Weight
Connections Oil
charge
Voltage Max.
Operating
current
/ Y
Max. power
consump
-
tion
Starting
current
(rotorlocked)
/ Y
Dis-
charge
line
DV
Suction
line
SV
m
3
/h A kW A kg mm (inch) mm (inch) Ltr.
HAX2/70-4 CO
2
T
2
6,20 / 7,40 15,1 9,3 57 / 75 149
18 22 2,5
HAX2/90-4 CO
2
T
7,70 / 9,30 20,5 12,0 82 / 107 160
HAX2 /110-4 CO
2
T
9,70 / 11,60 26,7 15,7 110 / 141 163
HA X2/130-4 CO
2
T
11,50 / 13,80 31,8 18,5 127 / 161 160
1
2
3
2
4
380-420VY/YY-3-50HzPW
440-480VY/YY-3-60HzPW
PW=Part Winding
Winding ratio: 70% / 30%
Tolerance (± 10%) relative to the mean value of the voltage range.
Othervoltagesandtypesofcurrentonrequest.
-Thespecicationsformax.powerconsumptionapplyfor50Hzoperation.
For60Hzoperation,thespecicationshavetobemultipliedbythefactor
1.2. The max. working current remains unchanged.
- Take account of the max. operating current / max. power consumption for
design of fuses, supply lines and safety devices. Fuse: Consumption category AC3
1
2
Allspecicationsarebasedontheaverageofthevoltagerange
Compression joint for steel pipes
3
4