4 | Compressor assembly
4.1 Setting up
4.2 Maximum permissible inclination
ATTENTION! Poor lubrication can damage the compressor.
Respect the stated values.
INFO! Newcompressorsarefactory-lledwithinertgas(3barnitrogen).
Leave this service charge in the compressor for as long as
possible and prevent the ingress of air.
Check the compressor for transport damage before starting any
work.
Fig. 8
Fig. 9
Fittings (e.g. pipe holders, additional units etc.) on the compressor are
permissible only following consultation with Bock.
Setup on an even surface or frame with sufcient load-bearing capac-
ity. Use all 4 fastening points.
Correct setup of the compressor and mounting of the belt drive are
decisive for running comfort, operating safety and the service life of
the compressor.
In the condition on delivery the compressor is provided with installa-
tion feet (see Fig. 8). Alternatively the compressor can also be bolted
directly, without installation feet, on the substructure.
A
a
A
a
A
max. 30°,
max. 2 minutes
a
max. 15°,
continuous
operation