4| Compressor assembly
4.9 Operating mode of the lockable service connections
Openingtheshut-offvalve:
a) Spindle1:turntotheleft(counter-clockwise)asfarasitwillgo.
—>Shut-offvalvefullyopened/
serviceconnection2closed
Fig.15
Fig.16
1
1
3
3
Pipeconnection
Pipeconnection
Openingtheserviceconnection(2):
b) Spindle1:Turn½-1rotationtotheright.
—>Serviceconnection2opened/shut-offvalveopened.
Connection3isprovidedforsafetydevicesandisnotlockable.