Instruction Manual

D
GB
F
E
25
96246-07.2014-DGbRu
9| Dimensions and connections
SV
DV
Suction line
Discharge line
see technical data, Chapter 7
A
Connection suction side, not lockable
1
/
8
“ NPTF
A1
Connection suction side, lockable
7
/
16
“ UNF
A2
Connection suction side, not lockable
1
/
8
“ NPTF
B
Connection discharge side, not lockable
1
/
8
“ NPTF
B1
Connection discharge side, lockable
7
/
16
“ UNF
B2
Connection discharge side, not lockable
7
/
16
“ UNF
C
Connection oil pressure safety switch
OIL
7
/
16
“ UNF
D
Connection oil pressure safety switch
LP
7
/
16
“ UNF
D1
Connection oil return from oil separator
5
/
8
“ UNF
E
Connection oil pressure gauge
7
/
16
“ UNF
F
Oil drain plug
M22 x 1,5
H
Oil charge plug
M22 x 1,5
J
Connection oil sump heater
M22 x 1,5
K
Sight glass
3 hole M6
L
Connection thermal protection thermostat
1
/
8
“ NPTF
ÖV
Connection
oil service valve
1
/
4
“ NPTF
P
Connection
differential oil pressure sensor
M20 x 1,5
Q
Connection oil temperature sensor
1
/
8
“ NPTF
View X
Oil sight glass
Possibility to connect to oil level regulator
Fig. 26
1
2
4
°
1
2
4
°
1
2
4
°
Ø 47,6
1
2
4
°
Three-hole connection for oil level regulator
makeESK,AC+R,CARLY(3xM6,10deep)
Three-hole connection for oil level regulator
makeTRAXOIL(3xM6x10deep)