Instruction Manual
20
D
GB
F
E
96246-07.2014-DGbRu
6.1 Preparation
6.2 Worktobecarriedout
6| Maintenance
Accessories available can be found on the Internet at www.bock.de.
6.4 Accessories
WARNING Beforestartinganyworkonthecompressor:
Switch off the compressor and secure it to prevent a restart.
Relieve compressor of system pressure.
Preventairfrominltratingthesystem!
Aftermaintenancehasbeenperformed:
Connect safety switch.
Evacuate compressor.
Releaseswitchlock.
To guarantee optimum operating safety and service life of the compressor, we recommend perfor-
mingserviceandcheckingworkatregularintervalsoftime:
Oilchange:
- In series plants produced in the factory not mandatory.
- In field installations or operating in the application limit range, first oil change after approx.
100 - 200 operating hours, then approx. every 3 years or 10,000 - 12,000 operating hours.
Dispose of old oil according to the regulations, observe national regulations.
Annualchecks: Oil level, tightness, running noise, pressures, temperatures, function of auxiliary
devices such as a oil sump heater, pressure switch. Comply with the national regulations!
F18 / ...
2735 3235
Designation
Ref. No. Ref. No.
Set gaskets 80904 80905
Valve plate kit 80894 80895
Kit piston / connecting rod 80890 80891
Kit capacity regulator LR12 80889 80879
Oil pump kit 80116
Kit shaft seal 80897
Oil SP 46, 1 liter 02279
Oil SE 55, 1 liter 02282
6.3 Spare parts recommendation
OnlyusegenuineBockspareparts!