Installation guide

Installation
Built-In Speedcook Ovens
Connect
Elect Jcal
Electrical Shock Hazard
Electrical ground is required on the appliance.
Do not connect the electrical supply until
appliance is permanently grounded.
Disconnect power to the junction box before
making the electrical connection.
This appliance must be grounded to a metallic,
permanent wiring system, or a grounding
connector should be connected to the
grounding terminal or wire lead on the appliance.
Failure to do so could result in fire, personal injury or electrical
shock.
3-ConducterBranchCircuit
BranchCircuit
120VAC Red
_ite or
Neutral Gray
120VAC Black
Red
Green
Whffe
Black
4-conductorBranchCircuit
BranchCircuit Oven
120VAC Red Red
120VAC Black Black
Bara or
6reen Green
GNB
Nsutral WhiteorGray White
When connecting to a 3-conductor branch
circuit:
- Connect oven red lead to branch circuit red
lead.
- Connect oven black lead to branch circuit
black lead.
- Connect oven green ground lead and white
lead to branch circuit neutral (white or
gray).
When connecting to a 4-conductor branch
circuit:
- Connect oven red lead to branch circuit red
lead.
- Connect oven black lead to branch circuit
black lead.
- Break connection between oven white lead
and oven green ground lead.
- Connect oven white lead to branch circuit
neutral lead (white or gray).
- Connect oven green ground lead to branch
circuit ground lead (green or bare copper).