Technical Specifications
Masoneilan Valves ValVue ESD Instruction Manual =| 317
© 2014 General Electric Company. All rights reserved.
53 6 4 PST_NEW_
DATA
3NoNoYesPST
New
Data
A PST Test is
stored in
memory and
has not yet
been archived
by ValVue
ESD.
Connect Val-
Vue ESD and
wait for the
flag to
self-clear. This
will indicate
that ValVue
ESD success-
fully archived
signature in its
database.
54 6 5 PST_DATA_
ERROR
3 Yes Yes No Saving
PST
Error
Upon comple-
tion of a PST, a
problem
occurred
when storing
event in mem-
ory.
1- Clear the
condition
using ValVue
ESD or HART
Host.
2- If condition
persists,
replace device
and report
problem at
svisup-
port@GE.com.
55 6 6 PNEUMATIC_T
RAIN
1YesNoYesPneum.
Train
Integ-
rity
1- The hourly
test detected
an unhealthy
I/P.
2- The hourly
test detected
an unhealthy
pneumatic
relay.
3- The hourly
test detected
a problem in
venting.
1,2 Re-run the
test from Val-
Vue ESD (TBT
button). If
alarm persists
contact the
factory.
3- Verify vent
condition.
Table 8 SVI II ESD Fault Matrix (Continued)
Seque
nce
Byte
#
Bit
#
FAULT Name Critical-
ity Of
Alarm
Auto-
mati-
cally
cleared
Can be
cleare
d
Per-
sists
across
resets
TEXT
For DD
&
Val-
Vue
ESD2
English
Probable
Cause
English
Recom-
mended
Action