Manual Find Stops
On some actuators it is possible that the automatic Find Stops procedure will not find the
correct end positions of the travel. A semi-automatic method of calibrating the stop positions
is provided.
When Manual Find Stops is selected, the valve is moved to full closed and you are asked to
respond when the valve has reached the full closed position. The valve is then moved to full
open and you are asked to respond when the valve has reached the full open position.
To run Manual Find Stops:
1. Right-click in the Calibrate screen and select Manual Find Stops (Figure 170).
Figure 170 Selecting Manual Find Stops