GE Oil & Gas Mooney* Flowgrid* Slam Shut Regulator Delivering accuracy, performance and protection
Industries ■■ Gas transmission ■■ Gas distribution ■■ Midstream gas ■■ Gas processing Applications ■■ Gas pipelines ■■ High occupancy buildings ■■ City gate stations ■■ Point of receipt Customer Benefits ■■ Easy maintenance with top entry design ■■ High accuracy and performance ■■ Over- or under-pressure protection ■■ ■■ ■■ ■■ ■■ ■■ 2 Resistant to sticking caused by freezing or debris Durable, with only one wear component Integration with Flowgrid regulators or can stand alone Qui
Meeting your needs for downstream pressure protection GE Oil & Gas has drawn upon our leading product technology and application expertise to develop the Mooney Flowgrid Slam Shut regulator. The Slam Shut regulator provides accurate, reliable secondary downstream pressure protection by shutting off the flow of gas when the sense or outlet pressure in the system either exceeds or drops below the set pressure point. The device can stand alone or be integrated with a Mooney Flowgrid regulator.
1-inch Flowgrid Slam Shut regulator The 1-inch Slam Shut is a safety shutoff regulator that closes with a linearly acting plug. The device has bubble-tight shutoff under all rated conditions and requires no minimum differential for full shutoff. Set points are adjustable and repeatable regardless of flow rate, inlet pressure, and temperature variations.
2-inch to 4-inch Flowgrid Slam Shut regulator The controller assembly for the Slam Shut can be supplied with either over- or under-pressure shutoff protection in three basic interchangeable configurations: 1. Series 50 single function controller (Figure 2), which provides either over- or under-pressure shutoff protection. 2.
Table 1 - Specifications Imperial Sizes 1-inch NPT & SWE DN 25, DN 32, DN 50, DN 80, 1.25-inch NPT & SWE DN 100 2-inch, 3-inch, 4-inch Stand alone or integrated into Flowgrid regulator Types Pressure Protection 1 Metric Temperature1 Standard: Over Optional: Over and/or under -20°F to 150°F -29°C to 65°C Maximum Operating Inlet Pressure 740 psig 50 bar Operating Sense Pressure 1-inch 2-4 inch 5 to 450 psig 10 psig to 50 psig 0.35 bar to 31 bar 0.69 bar to 31 bar Response Time <0 .
Principle of Operation for 2-4 inch Slam Shut During normal operation the latch mechanism holds the closure element (flapper) open as shown in Figure 5. The sense or downstream pressure is monitored by the over-pressure and under-pressure controller diaphragms, which convert the sense pressure into a force proportional to the pressure. The force is counter-balanced by the set point adjustment spring located in the spring case.
GE Oil & Gas 2822 S. 1030 West Salt Lake City, UT 84119 T: +1 801.487.2225 F: +1 801.487.2587 Visit us online at: www.ge.com/energy ©2012, General Electric Company All Rights Reserved *Trademark of General Electric Company GEA19398A Mooney Flowgrid Slam Shut Rev 06.